Skip to main content
Smart Cities Marketplace
Scalable cities

HIKARI, a 12.000m2 positive energy building with offices and dwellings

SRT Data

{"_id":"cluster:next-buildings-site-lyon_new-building-s-_hikari-a-12-000m2-positive-energy-building-with-offices-and-dwellings","_rev":"248-2e8083fadee01933ab2585939e218db9","document_type":"cluster","scis_id":"next-buildings-site-lyon_new-building-s-_hikari-a-12-000m2-positive-energy-building-with-offices-and-dwellings","building_general":{"building_general_number_buildings":"3","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"2015"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_apartments":36,"building_general_number_inhabitants":100,"building_general_number_occupants":600,"building_general_total_heated_net_room_area":12310,"building_general_total_cooled_net_room_area":8781},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2011,"new_building_value":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.27,"new_building_value":0.2},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.18},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.54,"new_building_value":0.27},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2,"new_building_value":1.4},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":70}],"ict":"Building Energy Management System","building_features":"Active sun influx control (shutters or louvers),Active ventilation control,Passive ventilation control (cooling by natural convention of cold air during summer nights),Thermal storage (including thermal inertia)"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":190000,"renewable_energy_financial":{}}],"detailed_ec":[{"technology":"absorption chiller","ec_name":"Heat\/district heat","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"250000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"70"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"12500"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"micro CHP","ec_name":"Energy crop","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"16","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.1","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.095,"reference":"0.0455","source":"proPellets Austria"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1440000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"89"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"136800"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"thermal storage","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"777000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"90"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.14","demo_site_fuel_cost":"0.054"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":69.5,"savings":73.5,"reference":"143","calculation":"215.8407798537774"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":34,"savings":32,"reference":"66","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":6.9874898456539,"savings":27.512510154346,"reference":"34.5","calculation":"20.30869212022746"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"savings":7,"reference":"7","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":0,"savings":36,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":400,"savings_programmed":"333300","savings_programmed_overridden":333700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":120,"savings_programmed":"114","savings_programmed_overridden":234},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"7.150922092585623","demonstration_building_overridden":103,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"149300"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":700}},"monitoring_data":{"monitoring_object":[{"monitoring_general_data":[],"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","renewable_energy_financial":[]}],"detailed_ec":[{"technology":"absorption chiller","ec_name":"Heat\/district heat","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"electrical storage","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"micro CHP","ec_name":"Energy crop","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"16","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.1","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0455","source":"proPellets Austria"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"thermal storage","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2016"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":67000,"renewable_energy_financial":[]}],"detailed_ec":[{"technology":"absorption chiller","ec_name":"Heat\/district heat","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":300000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":70}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"micro CHP","ec_name":"Energy crop","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"16","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.1","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0455","source":"proPellets Austria"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":528000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":89}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"thermal storage","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":985000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":89}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":113,"savings":30,"reference":"144","calculation":"152.72136474411047"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":35,"savings":30,"reference":"66","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":24,"savings":10,"reference":"34","calculation":"24.37043054427295"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":6,"savings":1,"reference":"7","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":33,"savings":3,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":169600,"savings_programmed_overridden":333700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":174,"savings_programmed_overridden":234},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.000002895068876713276","demonstration_building_overridden":38,"savings_programmed_overridden":0}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2017"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":180000,"renewable_energy_financial":[]}],"detailed_ec":[{"technology":"absorption chiller","ec_name":"Heat\/district heat","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":237000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":70}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"micro CHP","ec_name":"Energy crop","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"16","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.1","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0455","source":"proPellets Austria"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":466000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":89}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"thermal storage","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":956000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":88}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":111,"savings":33,"reference":"144","calculation":"149.3907392363932"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":38,"savings":28,"reference":"66","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":19,"savings":15,"reference":"34","calculation":"19.252640129975628"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":6,"savings":1,"reference":"7","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":33,"savings":3,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":169600,"savings_programmed_overridden":333700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":174,"savings_programmed_overridden":234},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.000007951200830105366","demonstration_building_overridden":43,"savings_programmed_overridden":0}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"cluster_type":"new-building-s-","revisions":[{"user":"rudy.rooth","date":"2018-08-02T10:19:31+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:02+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:53+00:00","reason":"Database update: _update_481_ReplaceSelectCommas #481"},{"user":"Clemens Tolboom","date":"2018-11-27T14:43:26+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:54+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:43:34+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-24T13:48:48+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:14+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:13+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T09:47:15+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T12:10:09+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T12:15:16+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:38+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-14T09:56:20+00:00","reason":"Database update: updateDocsForKeyValue #655"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:28+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:18:08+01:00","reason":"Database update: updateDocsRemoveKey #711"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:04+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:58+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"admin","date":"2019-08-15T14:20:00+02:00","reason":"Database update: updateDocsForKeyValue #418"}],"mon":{"year_2016":{"building_general":{"building_general_number_buildings":"3","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"2015"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_apartments":36,"building_general_number_inhabitants":100,"building_general_number_occupants":600,"building_general_total_heated_net_room_area":12310,"building_general_total_cooled_net_room_area":8781},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2011,"new_building_value":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.27,"new_building_value":0.2},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.18},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.54,"new_building_value":0.27},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2,"new_building_value":1.4},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":70}],"ict":"Building Energy Management System","building_features":"Active sun influx control (shutters or louvers),Active ventilation control,Passive ventilation control (cooling by natural convention of cold air during summer nights),Thermal storage (including thermal inertia)"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":67000,"renewable_energy_financial":{}}],"detailed_ec":[{"technology":"absorption chiller","ec_name":"Heat\/district heat","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"300000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"70"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"15000"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"micro CHP","ec_name":"Energy crop","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"16","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.1","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.095,"reference":"0.0455","source":"proPellets Austria"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"528000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"89"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"50160"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"thermal storage","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"985000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"89"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.14","demo_site_fuel_cost":"0.054"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":113,"savings":31,"reference":"144","calculation":"152.72136474411047"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":35,"savings":31,"reference":"66","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":24,"savings":10.5,"reference":"34.5","calculation":"24.37043054427295"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":6,"savings":1,"reference":"7","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":33,"savings":3,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":169600,"savings_programmed":"164100","savings_programmed_overridden":333700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":174,"savings_programmed":"60","savings_programmed_overridden":234},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"3.5638297872340425","demonstration_building_overridden":38,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"149300"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":700}}},"year_2017":{"building_general":{"building_general_number_buildings":"3","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"2015"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_apartments":36,"building_general_number_inhabitants":100,"building_general_number_occupants":600,"building_general_total_heated_net_room_area":12310,"building_general_total_cooled_net_room_area":8781},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2011,"new_building_value":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.27,"new_building_value":0.2},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.18},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.54,"new_building_value":0.27},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2,"new_building_value":1.4},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":70}],"ict":"Building Energy Management System","building_features":"Active sun influx control (shutters or louvers),Active ventilation control,Passive ventilation control (cooling by natural convention of cold air during summer nights),Thermal storage (including thermal inertia)"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":180000,"renewable_energy_financial":{}}],"detailed_ec":[{"technology":"absorption chiller","ec_name":"Heat\/district heat","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"237000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"70"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"11850"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"micro CHP","ec_name":"Energy crop","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"16","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.1","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.095,"reference":"0.0455","source":"proPellets Austria"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"466000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"89"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"44270"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"thermal storage","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"956000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"88"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.14","demo_site_fuel_cost":"0.054"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":111,"savings":33,"reference":"144","calculation":"149.3907392363932"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":38,"savings":28,"reference":"66","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":19,"savings":15.5,"reference":"34.5","calculation":"19.252640129975628"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":6,"savings":1,"reference":"7","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":33,"savings":3,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":169600,"savings_programmed":"164100","savings_programmed_overridden":333700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":174,"savings_programmed":"60","savings_programmed_overridden":234},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"9.787928221859707","demonstration_building_overridden":43,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"149300"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":700}}}}}

SRT ID

cluster:next-buildings-site-lyon_new-building-s-_hikari-a-12-000m2-positive-energy-building-with-offices-and-dwellings