Skip to main content
Smart Cities Marketplace
Scalable cities

Measure 1.1 Energy efficient refurbishment of the building - Lope de Vega

SRT Data

{"_id":"cluster:growsmarter-site-barcelona-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---lope-de-vega","_rev":"15-15218ff8a4de3af976b1cce8ebc00bb8","document_type":"cluster","scis_id":"growsmarter-site-barcelona-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---lope-de-vega","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1},"building_general_technical":{"building_general_building_type":"residential","building_general_total_heated_net_room_area":1015,"building_general_total_cooled_net_room_area":1015},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":1.42,"new_building_value":1.25,"old_building_value":2.05},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":1.28,"new_building_value":1.28,"old_building_value":1.28},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.75,"new_building_value":0.54,"old_building_value":1.8},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":2.46,"new_building_value":2.46,"old_building_value":2.46},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":3.1,"new_building_value":2,"old_building_value":5.17},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}],"ict":"Building Energy Management System","building_features":"Active sun influx control (shutters or louvers)"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":45.89,"savings":15.34,"reference":61.23,"old_building_value":76.99},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":14.56,"savings":9.7,"reference":24.26,"old_building_value":40.02},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":2.54,"savings":0.45,"reference":2.99,"old_building_value":2.99},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":12.1,"savings":5.18,"reference":17.28,"old_building_value":17.28},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":33.79,"savings":10.16,"reference":43.95,"old_building_value":59.71}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":0,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"revisions":[{"user":"Sigrid Granstrom","date":"2020-01-24T10:41:44+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T10:53:20+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T10:58:19+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T11:00:58+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T11:05:15+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T11:06:10+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T11:06:30+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T11:12:18+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-24T11:13:18+00:00","reason":"update"}],"mon":{"year_2019":{"building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1},"building_general_technical":{"building_general_building_type":"residential","building_general_total_heated_net_room_area":1015,"building_general_total_cooled_net_room_area":1015},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":1.42,"new_building_value":1.25,"old_building_value":2.05},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":1.28,"new_building_value":1.28,"old_building_value":1.28},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.75,"new_building_value":0.54,"old_building_value":1.8},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":2.46,"new_building_value":2.46,"old_building_value":2.46},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":3.1,"new_building_value":2,"old_building_value":5.17},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}],"ict":"Building Energy Management System","building_features":"Active sun influx control (shutters or louvers)"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":45.89,"savings":15.34,"reference":61.23,"old_building_value":76.99},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":20.1,"savings":5.75,"reference":25.85,"old_building_value":20.1},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0.38,"savings":0.23,"reference":0.61,"old_building_value":0.38},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":12.1,"savings":5.18,"reference":17.28,"old_building_value":17.28},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":30.86,"savings":4.71,"reference":35.57,"old_building_value":30.86}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":13946,"demonstration_building_overridden":13946,"savings_programmed":"2896","savings_programmed_overridden":16842},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":0,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_jobs_created":2.17}}}}}

SRT ID

cluster:growsmarter-site-barcelona-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---lope-de-vega