Skip to main content
Smart Cities Marketplace
Scalable cities

BEST4: Ainonkatu

SRT Data

{"_id":"cluster:eu-gugle-site-tampere_refurbished-building-s-_best4-ainonkatu","_rev":"216-ad8bf4649bb7f2b4bf4b215bc60b7450","document_type":"cluster","scis_id":"eu-gugle-site-tampere_refurbished-building-s-_best4-ainonkatu","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":"2","building_general_number_monitored_buildings":"2","building_general_number_year_completion":"1971"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":70,"building_general_number_inhabitants":112,"building_general_number_occupants":112,"building_general_total_gross_floor_area":5554,"old_building_general_total_heated_net_room_area":5000,"building_general_total_heated_net_room_area":5000,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":0},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2013,"new_building_value":2016,"old_building_value":1971},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.47,"new_building_value":0.6,"old_building_value":0.99},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.24,"new_building_value":0.47,"old_building_value":0.47},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.47,"new_building_value":0.44,"old_building_value":0.81},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.24,"new_building_value":0.47,"old_building_value":0.47},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":1,"new_building_value":1,"old_building_value":2.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":35,"new_building_value":0.35,"old_building_value":0.76}],"ict":"Building Energy Management System","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":208,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0.7,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2012},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.05,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"879000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"80"}]}],"detailed_ec":[{"technology":"heat pump: compression","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":208,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.7,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2012},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.05,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"280000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"2"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":340000,"reference":"35500"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":16600,"reference":"46600"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"reference":"0"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":16600,"reference":"46600","calculation":"14000"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":11,"calculation":"5.075"}]}],"grid_electricity_price":"0.102","demo_site_fuel_cost":"0.073"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":60,"savings":100,"reference":"160","calculation":"56","old_building_value":168},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":35,"savings":71,"reference":"106","calculation":"0","old_building_value":111},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0","old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":15,"savings":30,"reference":"45","calculation":"0","old_building_value":47},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":9,"savings":0,"reference":"9","calculation":"0","old_building_value":9}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":190000,"demonstration_building_programmed":"58240","demonstration_building_overridden":43000,"savings_programmed":"137000","savings_programmed_overridden":180000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":127,"demonstration_building_programmed":"95.2","demonstration_building_overridden":75,"savings_programmed":"45","savings_programmed_overridden":120},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":18,"demonstration_building_programmed":"0","demonstration_building_overridden":32,"savings_programmed_overridden":18}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":349000,"new_building_value":654000,"calculation":"340000"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":35000,"new_building_value":340000,"calculation":"340000"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","national_requirements":46600,"new_building_value":16600,"calculation":"16600"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":0,"calculation":"0"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":46600,"new_building_value":16600,"calculation":"14000"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","national_requirements":15,"new_building_value":11,"calculation":"5.083333333333333"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","national_requirements":7,"new_building_value":9,"calculation":""}],"social":{"new_building_social_citizens_involved":112,"new_building_social_jobs_created":11}},"revisions":[{"user":"rudy.rooth","date":"2018-08-01T16:02:31+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:02+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:51+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:42:34+00:00","reason":"Database update: _update_579_insert_row_total_operating_cost #579: inject row total_operating_costs"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:37+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:14+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:11+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T08:45:10+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:38+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-14T09:55:01+00:00","reason":"Database update: updateDocsForKeyValue #655"},{"user":"terttu.vainio","date":"2019-02-20T14:27:31+02:00","reason":"update"},{"user":"terttu.vainio","date":"2019-02-20T14:34:32+02:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:28+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"terttu.vainio","date":"2019-02-25T10:59:06+02:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:15:47+01:00","reason":"Database update: updateDocsForKeyValue #703"},{"user":"Clemens Tolboom","date":"2019-06-07T09:18:07+01:00","reason":"Database update: updateDocsRemoveKey #711"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:03+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:57+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"admin","date":"2019-08-15T14:25:57+02:00","reason":"Database update: updateDocsForKeyValue #836"}],"mon":{"year_2018":{"building_general":{"building_general_number_buildings":"2","building_general_number_monitored_buildings":"2","building_general_number_year_completion":"1971"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":70,"building_general_number_inhabitants":112,"building_general_number_occupants":112,"building_general_total_gross_floor_area":5554,"old_building_general_total_heated_net_room_area":5000,"building_general_total_heated_net_room_area":5000,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":0},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2013,"new_building_value":2016,"old_building_value":1971},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.47,"new_building_value":0.6,"old_building_value":0.99},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.24,"new_building_value":0.47,"old_building_value":0.47},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.47,"new_building_value":0.44,"old_building_value":0.81},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.24,"new_building_value":0.47,"old_building_value":0.47},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":1,"new_building_value":1,"old_building_value":2.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":35,"new_building_value":0.35,"old_building_value":0.76}],"ict":"Building Energy Management System","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":161,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0.5,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"879000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"90"}]}],"detailed_ec":[{"technology":"heat pump: compression","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":110,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.2,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"280000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"265"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":340000,"reference":"35500"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":22500,"reference":"60000"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"reference":"0"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":22500,"reference":"60000","calculation":"19600.000000000004"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":11,"calculation":"4.06"}]}],"grid_electricity_price":"0.102","demo_site_fuel_cost":"0.073"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":60,"savings":100,"reference":"160","calculation":"56","old_building_value":168},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":35,"savings":71,"reference":"106","calculation":"0","old_building_value":111},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0","old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":15,"savings":30,"reference":"45","calculation":"0","old_building_value":47},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":9,"savings":0,"reference":"9","calculation":"0","old_building_value":9}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":147000,"demonstration_building_programmed":"30800","demonstration_building_overridden":37000,"savings_programmed":"103000","savings_programmed_overridden":140000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":90,"demonstration_building_programmed":"67.2","demonstration_building_overridden":72,"savings_programmed":"13","savings_programmed_overridden":85},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":48,"demonstration_building_programmed":"0","demonstration_building_overridden":95,"savings_programmed_overridden":48}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":355000,"new_building_value":695000,"calculation":"340000"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":35000,"new_building_value":340000,"calculation":"340000"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","national_requirements":60000,"new_building_value":22500,"calculation":"22500"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":0,"calculation":"0"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":60000,"new_building_value":22500,"calculation":"19600.000000000004"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","national_requirements":11,"new_building_value":8,"calculation":"4.066666666666666"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","national_requirements":9,"new_building_value":12,"calculation":""}],"social":{"new_building_social_citizens_involved":112,"new_building_social_jobs_created":11}}}}}

SRT ID

cluster:eu-gugle-site-tampere_refurbished-building-s-_best4-ainonkatu