Skip to main content
European Commission logo
Smart Cities Marketplace

Building refurbishment : Mistral

SRT Data

{"_id":"cluster:city-zen-site-grenoble_refurbished-building-s-_building-refurbishment-mistral","_rev":"23-c5624b394075d978bf1e2d935963cd0d","document_type":"cluster","scis_id":"city-zen-site-grenoble_refurbished-building-s-_building-refurbishment-mistral","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":3,"building_general_number_monitored_buildings":3,"building_general_number_year_completion":2019},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":199,"building_general_number_inhabitants":661,"building_general_number_occupants":661,"building_general_total_gross_floor_area":20755,"old_building_general_total_heated_net_room_area":14621,"building_general_total_heated_net_room_area":14621,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":0},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2005,"new_building_value":2018},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":1.395},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.28,"new_building_value":0.13,"old_building_value":0.26},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.45,"new_building_value":0.206,"old_building_value":0.43},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.33,"new_building_value":0.391,"old_building_value":0.73},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.6,"new_building_value":1.5,"old_building_value":3.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":60,"old_building_value":80}],"ict":"Demand Response","building_features":"Active sun influx control (shutters or louvers)"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":100,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"2000555"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"95"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":100,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.58,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1718,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"145107"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"100"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":100,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":1125852},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":95}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"56292.600000000006"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":100,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.58,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1718,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":69804},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":100}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"11992.3272"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.15","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":57.61,"savings":12.310000000000002,"reference":69.92,"old_building_value":103.38},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":37.74,"savings":7.479999999999997,"reference":45.22,"old_building_value":78.04},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":0,"old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":19.5,"savings":-0.030000000000001137,"reference":19.47,"old_building_value":18.35},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":1.26,"savings":2.0700000000000003,"reference":3.33,"calculation":"4.774228848915943","old_building_value":4.81}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":412806,"demonstration_building_programmed":"119565.6"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":282},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":53}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"68284.9272"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":661}},"revisions":[{"user":"Marko Popovic","date":"2019-11-18T15:36:35+00:00","reason":"update"},{"user":"Marko Popovic","date":"2019-11-18T16:13:47+00:00","reason":"update"},{"user":"Marko Popovic","date":"2019-11-20T08:42:41+00:00","reason":"update"},{"user":"Marko Popovic","date":"2019-11-20T10:33:06+00:00","reason":"update"},{"user":"Marko Popovic","date":"2019-11-20T10:42:40+00:00","reason":"update"},{"user":"Marko Popovic","date":"2019-11-20T15:24:34+00:00","reason":"update"},{"user":"Marko Popovic","date":"2020-06-25T13:33:23+01:00","reason":"update"},{"user":"Marko Popovic","date":"2020-06-25T14:26:17+01:00","reason":"update"},{"user":"nathalie.moyon","date":"2020-08-04T18:17:05+02:00","reason":"update"}]}

SRT ID

cluster:city-zen-site-grenoble_refurbished-building-s-_building-refurbishment-mistral