Skip to main content
Smart Cities Marketplace
Scalable cities

Schilfpark DH with hydrogen

SRT Data

{"document_type":"cluster","scis_id":"mysmartlife-hamburg_dhc-extension_schilfpark-dh-with-hydrogen","cluster_type":"dhc-extension","energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"new developed network","energy_systems_year_completion":"2019"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":1200},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":273},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":7},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling"},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.1},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":70},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":50},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":70},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":50},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":70}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Other","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":0},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2021},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"2493749"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"104.2"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":2597997},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":2416137},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"demonstration_building_overridden":342352},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":0,"demonstration_building_overridden":1864296}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Domestic gas - from gas tank","kpi_name":"Total energy cost Domestic gas - from gas tank","unit":"\u20ac\/a"}],"social":{"new_building_floor_area":27708}},"_id":"cluster:mysmartlife-hamburg_dhc-extension_schilfpark-dh-with-hydrogen","revisions":[{"user":"mSLHamburg","date":"2021-06-21T15:29:41+02:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-04T16:02:53+01:00","reason":"Renamed from 'cluster:mysmartlife-hamburg_dhc-extension_energy-system-s-integration---infractructure---dummy' to 'cluster:mysmartlife-hamburg_dhc-extension_schilfpark-dh-with-hydrogen'"},{"user":"Kaja Aniol","date":"2022-01-04T16:18:43+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-04T16:44:53+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-04T16:48:31+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:11:59+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:16:28+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:16:44+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:17:30+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:19:18+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:49:33+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:50:39+01:00","reason":"update"},{"user":"Kaja Aniol","date":"2022-01-05T11:52:24+01:00","reason":"update"}],"mon":{"year_2020":{"energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"new developed network","energy_systems_year_completion":"2019"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":1200},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":273},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":7},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling"},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.1},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":70},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":50},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":70},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":50},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":70}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Other","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":0},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2021},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1961722"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"108.0"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":2117840},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":1969591},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"demonstration_building_overridden":342352},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":0,"demonstration_building_overridden":1864296}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Domestic gas - from gas tank","kpi_name":"Total energy cost Domestic gas - from gas tank","unit":"\u20ac\/a"}],"social":{"new_building_floor_area":27708}}}}}

SRT ID

cluster:mysmartlife-hamburg_dhc-extension_schilfpark-dh-with-hydrogen