Skip to main content
Smart Cities Marketplace
Scalable cities

21 apartment building (Mogel)

SRT Data

{"_id":"cluster:zenn-site-eibar_refurbished-building-s-_21-apartment-building-mogel-","_rev":"202-682fdd18dae1fb06234035bfd13a8691","document_type":"cluster","scis_id":"zenn-site-eibar_refurbished-building-s-_21-apartment-building-mogel-","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":"15","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"1949"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":150,"building_general_number_inhabitants":302,"old_building_general_total_heated_net_room_area":9450,"building_general_total_heated_net_room_area":9450,"old_building_general_total_cooled_net_room_area":9450,"building_general_total_cooled_net_room_area":9450},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.41,"new_building_value":0.2,"old_building_value":2.86},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.73,"new_building_value":0.36,"old_building_value":1.6},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.5,"new_building_value":2.1,"old_building_value":2.1},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.2,"new_building_value":2.7,"old_building_value":2.7},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":0.54,"old_building_value":0.54}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"solar thermal collectors","installed_heat":72765,"renewable_energy_financial":{"total_investment_costs":228658,"total_grants":0}}],"old_detailed_ec":[{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"547000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"DHW (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"284000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":303,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.464,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"249400"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"100"}]}],"detailed_ec":[],"grid_electricity_price":"0.14722712","demo_site_fuel_cost":"0.0530905"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":74,"savings":39,"reference":"113","calculation":"7.7","old_building_value":113},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":15,"savings":42,"reference":"57","calculation":"0","old_building_value":57},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0","old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":29,"savings":0,"reference":"29","calculation":"0","old_building_value":29},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":29,"savings":-3,"reference":"26","calculation":"0","old_building_value":26}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":232470,"demonstration_building_overridden":123795,"savings_programmed":"108675","savings_programmed_overridden":232470},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":102,"demonstration_building_overridden":41,"savings_programmed":"61","savings_programmed_overridden":102},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_programmed":"100","demonstration_building_overridden":11,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","new_building_value":1769500,"calculation":"228658"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":1540839,"calculation":"228658"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":0,"calculation":"0"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"0"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":52},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","calculation":""}],"social":{}},"monitoring_data":{"refurbished_monitoring_object":[{"monitoring_general_data":{"monitoring_general_data_year":"2016"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"solar thermal collectors","installed_heat":69930,"renewable_energy_financial":[]}],"detailed_ec":[]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":127},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":62},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"old_building":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":26},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":39}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building":377000,"demonstration_building_overridden":178000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building":212,"demonstration_building_overridden":146},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building":0,"demonstration_building_overridden":8.3}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","reference":51},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2014"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"solar thermal collectors","renewable_energy_financial":[]}],"detailed_ec":[]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"revisions":[{"user":"rudy.rooth","date":"2018-08-01T10:56:00+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:03+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:54+00:00","reason":"Database update: _update_481_ReplaceSelectCommas #481"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:56+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:42:35+00:00","reason":"Database update: _update_579_insert_row_total_operating_cost #579: inject row total_operating_costs"},{"user":"Clemens Tolboom","date":"2018-12-11T10:43:34+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:16+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:14+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T11:12:22+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-11T09:28:48+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-11T09:32:47+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:39+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:29+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:15:48+01:00","reason":"Database update: updateDocsForKeyValue #703"},{"user":"Clemens Tolboom","date":"2019-06-07T09:18:08+01:00","reason":"Database update: updateDocsRemoveKey #711"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:07+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:31:03+01:00","reason":"Database update: updateDocsForKeyValue #773"}],"mon":{"year_2016":{"building_general":{"building_general_number_buildings":"15","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"1949"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":150,"building_general_number_inhabitants":302,"old_building_general_total_heated_net_room_area":9450,"building_general_total_heated_net_room_area":9450,"old_building_general_total_cooled_net_room_area":9450,"building_general_total_cooled_net_room_area":9450},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.41,"new_building_value":0.2,"old_building_value":2.86},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.73,"new_building_value":0.36,"old_building_value":1.6},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.5,"new_building_value":2.1,"old_building_value":2.1},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.2,"new_building_value":2.7,"old_building_value":2.7},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":0.54,"old_building_value":0.54}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"solar thermal collectors","installed_heat":69930,"renewable_energy_financial":{"total_investment_costs":228658,"total_grants":0}}],"old_detailed_ec":[{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"547000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"DHW (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"284000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":303,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.464,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"249400"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"100"}]}],"detailed_ec":[],"grid_electricity_price":"0.14722712","demo_site_fuel_cost":"0.0530905"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":127,"savings":-14,"reference":"113","calculation":"7.4","old_building_value":113},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":62,"savings":-5,"reference":"57","calculation":"0","old_building_value":57},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0","old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":26,"savings":3,"reference":"29","calculation":"0","old_building_value":29},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":39,"savings":-13,"reference":"26","calculation":"0","old_building_value":26}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":377000,"demonstration_building_overridden":178000,"savings_programmed":"54470","savings_programmed_overridden":232470},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":212,"demonstration_building_overridden":146,"savings_programmed":"-44","savings_programmed_overridden":102},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_programmed":"100","demonstration_building_overridden":8.3,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","new_building_value":1769500,"calculation":"228658"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":1540839,"calculation":"228658"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":0,"calculation":"0"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"0"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":51},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","calculation":""}],"social":{}}}}}

SRT ID

cluster:zenn-site-eibar_refurbished-building-s-_21-apartment-building-mogel-

Building aspects