Skip to main content
European Commission logo
Smart Cities Marketplace
Apply for technical assistance

Tito Maccio Plauto School

SRT Data

{"_id":"cluster:school-of-the-future-site-cesena_refurbished-building-s-_tito-maccio-plauto-school","_rev":"202-b4eeb46242461fe9bbf41a27607432be","document_type":"cluster","scis_id":"school-of-the-future-site-cesena_refurbished-building-s-_tito-maccio-plauto-school","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":"1"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_total_gross_floor_area":6420,"building_general_total_heated_net_room_area":6420},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)"},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)"},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)"},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)"},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}],"building_features":"Passive ventilation control (cooling by natural convention of cold air during summer nights)"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":86670,"renewable_energy_financial":{"total_investment_costs":88596}}],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.234","demo_site_fuel_cost":"0.094"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":32,"savings":120,"reference":"152","calculation":"13.5"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":23,"savings":120,"reference":"143","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":1,"savings":0,"reference":"1","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":12,"savings":0,"reference":"12","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":38520,"savings_programmed":"243960","savings_programmed_overridden":282480},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":30,"savings_programmed":"190","savings_programmed_overridden":220},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"100"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":954769,"calculation":"88596"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","calculation":"88596"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"0"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","national_requirements":11}],"social":{}},"monitoring_data":{"refurbished_monitoring_object":[{"monitoring_general_data":{"monitoring_general_data_year":"2014"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","renewable_energy_financial":[]}],"detailed_ec":[]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":256800,"savings":789660,"old_building":"1046460"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":154080,"savings":789660,"old_building":"943740"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":38520,"savings":0,"old_building":"38520"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":60990,"savings":16050,"old_building":"77040"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":57780,"old_building":301740},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":256800,"old_building":1508700},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"revisions":[{"user":"rudy.rooth","date":"2018-08-02T12:57:38+01:00"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:55+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:42:35+00:00","reason":"Database update: _update_579_insert_row_total_operating_cost #579: inject row total_operating_costs"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:15+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:14+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-06T08:34:25+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-06T08:45:10+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:59+01:00","reason":"Database update: updateDocsForKeyValue #773"}],"mon":{"year_2014":{"building_general":{"building_general_number_buildings":"1"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_total_gross_floor_area":6420,"building_general_total_heated_net_room_area":6420},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)"},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)"},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)"},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)"},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}],"building_features":"Passive ventilation control (cooling by natural convention of cold air during summer nights)"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":86670,"renewable_energy_financial":{"total_investment_costs":88596}}],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.234","demo_site_fuel_cost":"0.094"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":40,"savings":112,"reference":"152","calculation":"13.5","old_building_value":163},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":24,"savings":119,"reference":"143","calculation":"0","old_building_value":147},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":6,"savings":0,"reference":"6","calculation":"0","old_building_value":6},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":9.5,"savings":2.5,"reference":"12","calculation":"0","old_building_value":12}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":301740,"demonstration_building_overridden":57780,"savings_programmed":"224700","savings_programmed_overridden":282480},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":235,"demonstration_building_overridden":40,"savings_programmed":"180","savings_programmed_overridden":220},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"100"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":954769,"calculation":"88596"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","calculation":"88596"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"0"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","national_requirements":11}],"social":{}}}}}

SRT ID

cluster:school-of-the-future-site-cesena_refurbished-building-s-_tito-maccio-plauto-school