Skip to main content
European Commission logo
Smart Cities Marketplace
Apply for technical assistance

Refurbished Building

SRT Data

{"_id":"cluster:replicate-site-san-sebastian-_refurbished-building-s-_refurbished-building-","_rev":"226-b24a100522573042527dbab0a3d04bbe","document_type":"cluster","scis_id":"replicate-site-san-sebastian-_refurbished-building-s-_refurbished-building-","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":10,"building_general_number_monitored_buildings":10,"building_general_number_year_completion":2019},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":156,"building_general_number_inhabitants":433,"building_general_number_occupants":433,"building_general_total_gross_floor_area":18350,"building_general_total_heated_net_room_area":14497},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2006},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.86,"new_building_value":2.43,"old_building_value":0.55},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.38,"new_building_value":2.7,"old_building_value":0.38},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":1.37,"old_building_value":0.33},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.49,"new_building_value":2.9,"old_building_value":0.37},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.7,"new_building_value":5.7,"old_building_value":1.9},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":48,"new_building_value":0.62,"old_building_value":0.14}]},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[],"detailed_ec":[{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":4300000},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":3300000},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":72,"savings":194,"reference":266},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":12,"savings":0,"reference":12}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":317995,"savings_programmed":"856925","savings_programmed_overridden":1174920},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":98,"savings_programmed":"267","savings_programmed_overridden":365},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","new_building_value":4300000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":3300000},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":156119},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":7.5}],"social":{"new_building_social_citizens_involved":433}},"revisions":[{"user":"rudy.rooth","date":"2018-08-02T12:22:48+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:02+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:54+00:00","reason":"Database update: _update_481_ReplaceSelectCommas #481"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:55+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:42:35+00:00","reason":"Database update: _update_579_insert_row_total_operating_cost #579: inject row total_operating_costs"},{"user":"Clemens Tolboom","date":"2018-12-11T10:43:34+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:15+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:14+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T10:42:28+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:39+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-14T09:55:02+00:00","reason":"Database update: updateDocsForKeyValue #655"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:29+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:15:47+01:00","reason":"Database update: updateDocsForKeyValue #703"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:05+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:59+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"admin","date":"2019-08-15T14:20:01+02:00","reason":"Database update: updateDocsForKeyValue #418"},{"user":"admin","date":"2019-08-15T14:25:58+02:00","reason":"Database update: updateDocsForKeyValue #836"},{"user":"Nora Mendoza","date":"2020-09-02T11:49:34+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-02T13:11:25+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-03T07:05:40+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-03T08:12:46+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-09T09:43:12+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-09T09:50:48+01:00","reason":"update"}],"mon":{"year_2019":{"building_general":{"building_general_number_buildings":10,"building_general_number_monitored_buildings":10,"building_general_number_year_completion":2019},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":156,"building_general_number_inhabitants":433,"building_general_number_occupants":433,"building_general_total_gross_floor_area":18350,"building_general_total_heated_net_room_area":14497},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2006},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.86,"new_building_value":2.43,"old_building_value":0.55},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.38,"new_building_value":2.7,"old_building_value":0.38},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":1.37,"old_building_value":0.33},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.49,"new_building_value":2.9,"old_building_value":0.37},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.7,"new_building_value":5.7,"old_building_value":1.9},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":48,"new_building_value":0.62,"old_building_value":0.14}]},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[],"detailed_ec":[{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":4300000},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":3300000},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":72,"savings":194,"reference":266},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":12,"savings":0,"reference":12}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":317995,"savings_programmed":"856925","savings_programmed_overridden":1174920},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":98,"savings_programmed":"267","savings_programmed_overridden":365},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","new_building_value":4300000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":3300000},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":156119},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":7.5}],"social":{"new_building_social_citizens_involved":433}}}}}

SRT ID

cluster:replicate-site-san-sebastian-_refurbished-building-s-_refurbished-building-

Building aspects