Skip to main content
Smart Cities Marketplace
Scalable cities

Energy Generation

SRT Data

{"_id":"cluster:replicate-site-san-sebastian-_dhc-extension_energy-generation","_rev":"197-47a54f116f2cc16d939d1ec2ca1be3ae","document_type":"cluster","scis_id":"replicate-site-san-sebastian-_dhc-extension_energy-generation","cluster_type":"dhc-extension","energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"extension of existing network","energy_systems_year_completion":"2018"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":7400},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth"},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1458},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":3},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling"},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating "},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":90},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":70},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":70},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":50},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C"}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Domestic gas - grid-bound","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"6366816"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":5600000},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a"},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a"},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":1941878.88},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":8658869.76}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","reference_system":4000000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","reference_system":990964},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","reference_system":613000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","reference_system":21.4},{"key":"total_energy_cost_Domestic gas - grid-bound","kpi_name":"Total energy cost Domestic gas - grid-bound","unit":"\u20ac\/a","calculation":"422756.5824"}],"social":{}},"revisions":[{"user":"rudy.rooth","date":"2019-03-21T09:22:00+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-21T09:22:14+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:05+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:59+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"Nora Mendoza","date":"2020-09-02T12:03:22+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-02T12:03:42+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-02T12:15:32+01:00","reason":"update"},{"user":"Nora Mendoza","date":"2020-09-09T09:26:54+01:00","reason":"update"}],"mon":{"year_2019":{"energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"extension of existing network","energy_systems_year_completion":"2018"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":7400},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth"},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1458},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":3},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling"},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating "},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":90},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":70},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":70},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":50},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C"}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Domestic gas - grid-bound","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"6366816"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":5600000},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a"},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a"},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":1941878.88},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":8658869.76}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","reference_system":4000000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","reference_system":990964},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","reference_system":613000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","reference_system":21.4},{"key":"total_energy_cost_Domestic gas - grid-bound","kpi_name":"Total energy cost Domestic gas - grid-bound","unit":"\u20ac\/a","calculation":"422756.5824"}],"social":{}}}}}

SRT ID

cluster:replicate-site-san-sebastian-_dhc-extension_energy-generation