Skip to main content
Smart Cities Marketplace
Scalable cities

Heat Plant

SRT Data

{"_id":"cluster:remourban-site-tepeba-_dhc-extension_heat-plant","_rev":"197-687c476acb08903e812e56bc499e9d12","document_type":"cluster","scis_id":"remourban-site-tepeba-_dhc-extension_heat-plant","cluster_type":"dhc-extension","energy_systems_general":{"energy_systems_dhc_type":"District heating&cooling","energy_systems_dhc_construction":"new developed network"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":450},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":210},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":57},{"key":"network_losses","intervention_name":"network losses","unit":"%"},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling"},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating "},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":60},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":45},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":7},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":12},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C"}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"729612"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"75"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":480172},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":360129},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":249440},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":187080}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":222531.66,"savings_programmed":"166127.34","reference_system":388659},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":992272.32,"savings_programmed":"971132.6799999999","reference_system":1963405}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":550000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":7580},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":36},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"36480.6"}],"social":{"new_building_social_citizens_involved":386,"new_building_floor_area":10570}},"revisions":[{"user":"rudy.rooth","date":"2019-03-21T09:09:29+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-21T09:10:00+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:05+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:59+01:00","reason":"Database update: updateDocsForKeyValue #773"}]}

SRT ID

cluster:remourban-site-tepeba-_dhc-extension_heat-plant