Skip to main content
Smart Cities Marketplace
Scalable cities

Data Center SE-WW1

SRT Data

{"_id":"cluster:ready-site-v-xj-_dhc-extension_data-center-se-ww1","_rev":"124-24236839f2d8cb9fdc539e79ef16a049","document_type":"cluster","scis_id":"ready-site-v-xj-_dhc-extension_data-center-se-ww1","cluster_type":"dhc-extension","energy_systems_general":{"energy_systems_dhc_type":"District cooling","energy_systems_dhc_construction":"extension of existing network","energy_systems_year_completion":"2017"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":0},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":900},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":2},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":0},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0.04},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":12},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":19},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":15},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":23},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C"}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Biowaste","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":3.41,"reference":"98","source":"as for biogas (lack of data)"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0,"reference":"2.71","source":"as for biogas (lack of data)"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.081,"reference":"0.05","source":"as for biogas (lack of data)"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"542092"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a"},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a"},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":1292000},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":597330}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":1848.53372},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":1236000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":618000},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a","value":0},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":0},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a","value":0},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":92000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_floor_area":350}},"revisions":[{"user":"rudy.rooth","date":"2019-02-07T10:16:27+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:59+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rmh","date":"2020-09-22T08:50:19+01:00","reason":"update"},{"user":"rmh","date":"2020-09-22T09:02:11+01:00","reason":"update"},{"user":"rmh","date":"2020-09-22T10:21:03+01:00","reason":"update"},{"user":"rmh","date":"2020-09-22T10:36:52+01:00","reason":"update"},{"user":"rmh","date":"2020-09-22T10:38:59+01:00","reason":"update"},{"user":"rmh","date":"2020-09-23T08:41:17+01:00","reason":"update"},{"user":"rmh","date":"2020-09-23T11:44:28+01:00","reason":"update"},{"user":"rmh","date":"2020-10-12T14:55:13+01:00","reason":"update"},{"user":"Thomas Natiesta","date":"2021-04-26T21:21:16+02:00","reason":"update"},{"user":"Thomas Natiesta","date":"2021-04-26T21:33:22+02:00","reason":"update"}],"mon":{"year_2019":{"energy_systems_general":{"energy_systems_dhc_type":"District cooling","energy_systems_dhc_construction":"extension of existing network","energy_systems_year_completion":"2017"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":0},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":900},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":2},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":0},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0.04},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":12},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":19},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":15},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":23},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C"}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Biowaste","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":3.41,"reference":"98","source":"as for biogas (lack of data)"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0,"reference":"2.71","source":"as for biogas (lack of data)"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.081,"reference":"0.05","source":"as for biogas (lack of data)"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"542092"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a"},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a"},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":1292000},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":597330}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":1848.53372},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":1236000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":618000},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a","value":0},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":0},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a","value":0},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":92000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_floor_area":350}}}}}

SRT ID

cluster:ready-site-v-xj-_dhc-extension_data-center-se-ww1