Skip to main content
Smart Cities Marketplace
Scalable cities

Brescia Waste heat revalorisation plant

SRT Data

{"_id":"cluster:pitagoras-site-brescia_co-generation_brescia-waste-heat-revalorisation-plant","_rev":"97-2d373ab61964df9ff1c30eeb4f006529","document_type":"cluster","scis_id":"pitagoras-site-brescia_co-generation_brescia-waste-heat-revalorisation-plant","cluster_type":"co-generation","energy_systems_general":{"energy_systems_technology_used_generation":"Organic Rankine Cycle","energy_systems_year_completion":"2016"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_output_excl_peak_load","intervention_name":"Maximum thermal output of plant excluding peak load boiler","unit":"kWth","value":10000},{"key":"maximal_electrical_output","intervention_name":"maximum electrical output of plant","unit":"kWel","value":1880},{"key":"design_power_heat_ratio","intervention_name":"design power to heat ratio","unit":"kWel\/kWth","value":0.188},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":107}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Waste heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"0","source":"SCIS estimation for pure waste heat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1","source":"SCIS estimation for pure waste heat"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.03","source":"Ecofys"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total Energy Generation [output] - Heat","unit":"kWh\/a","value":26500000},{"key":"total_energy_generation_electricity","kpi_name":"Total Energy Generation [output] - Electricity","unit":"kWh\/a","value":4200000},{"key":"energy_carrier_peak_load_supply","kpi_name":"Energy carrier for peak load supply","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","reference_system":40360000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":12000000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":2500000},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a","value":400000},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":500000},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","value":12},{"key":"total_energy_cost_Waste heat","kpi_name":"Total energy cost Waste heat","unit":"\u20ac\/a","value":0}],"social":{"new_building_floor_area":265000}},"revisions":[{"user":"rudy.rooth","date":"2019-02-14T16:19:42+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-14T16:20:20+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-18T15:20:02+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-18T15:28:11+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-20T14:44:02+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-20T14:56:38+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-21T08:14:18+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-21T08:20:18+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-05-27T12:32:23+01:00","reason":"update"},{"user":"rudy.rooth","date":"2019-05-27T12:32:54+01:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:05:46+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:04+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:58+01:00","reason":"Database update: updateDocsForKeyValue #773"}],"mon":{"year_2017":{"energy_systems_general":{"energy_systems_technology_used_generation":"Organic Rankine Cycle","energy_systems_year_completion":"2016"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_output_excl_peak_load","intervention_name":"Maximum thermal output of plant excluding peak load boiler","unit":"kWth","value":10000},{"key":"maximal_electrical_output","intervention_name":"maximum electrical output of plant","unit":"kWel","value":1880},{"key":"design_power_heat_ratio","intervention_name":"design power to heat ratio","unit":"kWel\/kWth","value":0.188},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":107}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Waste heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":0,"reference":"0","source":"SCIS estimation for pure waste heat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0,"reference":"1","source":"SCIS estimation for pure waste heat"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0,"reference":"0.03","source":"Ecofys"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"38870000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"79"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total Energy Generation [output] - Heat","unit":"kWh\/a","value":20991000},{"key":"total_energy_generation_electricity","kpi_name":"Total Energy Generation [output] - Electricity","unit":"kWh\/a","value":1915000},{"key":"energy_carrier_peak_load_supply","kpi_name":"Energy carrier for peak load supply","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"savings_programmed":"5553000","reference_system":5553000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":0,"savings_programmed":"29021000","reference_system":29021000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":12000000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":2500000},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a","value":153200},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":314865},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":180000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":12},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","value":12},{"key":"total_energy_cost_Waste heat","kpi_name":"Total energy cost Waste heat","unit":"\u20ac\/a","value":0,"calculation":"0"}],"social":{"new_building_floor_area":209910}}}}}

SRT ID

cluster:pitagoras-site-brescia_co-generation_brescia-waste-heat-revalorisation-plant