Skip to main content
Smart Cities Marketplace
Scalable cities

Brede School

SRT Data

{"_id":"cluster:next-buildings-site-amsterdam_new-building-s-_brede-school","_rev":"322-9c84c8648d79bb6ed9c67014b83eaadc","document_type":"cluster","scis_id":"next-buildings-site-amsterdam_new-building-s-_brede-school","building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":350,"building_general_total_gross_floor_area":6800,"building_general_total_heated_net_room_area":6500,"building_general_total_cooled_net_room_area":6500},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","new_building_value":2011},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.5},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.25,"new_building_value":0.12},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.15},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.3,"new_building_value":0.12},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":0.8},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":0.4}],"ict":"Building Energy Management System"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":113000,"renewable_energy_financial":{"total_investment_costs":201600,"total_operating_costs":4000,"total_grants":60000,"feed_tariff_calculated":"6.788111217641419","feed_tariff":9.5}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":62,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.3,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2011},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"123760"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":125000,"reference":"75000","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":2500,"reference":"3500","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":40000,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":12000,"reference":"17000","calculation":"8663.2"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":2.5,"calculation":"1.6666666666666667"}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":28,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2011},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.05,"reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"53040"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":75000,"reference":"130000","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":1500,"reference":"2600","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":25000,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":770,"reference":"5000","calculation":"2652"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":0,"calculation":"-15.0093808630394"}]}],"grid_electricity_price":"0.22","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":27,"savings":74,"reference":"101","calculation":"44.58461538461538"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":12,"savings":40,"reference":"52"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":7,"savings":12,"reference":"19"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":3,"savings":10,"reference":"13"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":5,"savings":11,"reference":"16"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"9158.24","demonstration_building_overridden":85500,"savings_programmed":"53600","savings_programmed_overridden":139100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"50.296615384615386","demonstration_building_overridden":68,"savings_programmed":"62","savings_programmed_overridden":130},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"38.99240855762595","demonstration_building_overridden":52,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":12862500,"new_building_value":14000000,"calculation":"401600"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":1140000,"calculation":"401600"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","national_requirements":115000,"new_building_value":100000,"calculation":"8000"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":300000,"calculation":"125000"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":51000,"new_building_value":27770,"calculation":"11315.2"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","calculation":"21.972273083965472"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":400,"new_building_social_jobs_created":5}},"monitoring_data":{"monitoring_object":[{"monitoring_general_data":[],"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","renewable_energy_financial":[]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and cooling and DHW","ec_data_environmental":[],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"heating and cooling and DHW","ec_data_environmental":[],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"}]}]},"monitoring_kpis":{"technical":[],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2015"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":105000,"renewable_energy_financial":{"total_operating_costs":0,"feed_tariff":7}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":62,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.3,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"443300"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":2500,"reference":"3500"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":31500,"reference":"17000"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":28,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.15,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.05,"reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"127400"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":1500,"reference":"2600"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":1386,"reference":"5000"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":104.1,"savings":-3.1,"reference":"101"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":55,"savings":-2.4,"reference":"52.6"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":19.6,"savings":-0.8,"reference":"18.8"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":13.2,"savings":0,"reference":"13.2"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":16.2,"savings":0,"reference":"16.2"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":80542,"savings_programmed_overridden":139100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":63.8,"savings_programmed_overridden":130},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_overridden":13.4,"savings_programmed_overridden":0}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":77686},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2016"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":95000,"renewable_energy_financial":{"total_operating_costs":0}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":62,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.3,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"399100"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":28,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.15,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"131300"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":102.2,"savings":-1.2,"reference":"101"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":49,"savings":3.5,"reference":"52.5"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":20.2,"savings":-1.4,"reference":"18.8"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":12.4,"savings":0.8,"reference":"13.2"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":20.6,"savings":-4.4,"reference":"16.2"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":91353,"savings_programmed_overridden":139100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":72.9,"savings_programmed_overridden":130},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_overridden":12.5,"savings_programmed_overridden":0}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"cluster_type":"new-building-s-","revisions":[{"user":"rudy.rooth","date":"2018-08-15T15:17:42+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:02+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:53+00:00","reason":"Database update: _update_481_ReplaceSelectCommas #481"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:54+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:14+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:13+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T09:44:35+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-07T09:44:45+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T11:04:03+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T11:17:17+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T11:18:15+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:38+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-14T09:56:20+00:00","reason":"Database update: updateDocsForKeyValue #655"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:28+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:15:47+01:00","reason":"Database update: updateDocsForKeyValue #703"},{"user":"Clemens Tolboom","date":"2019-06-07T09:18:08+01:00","reason":"Database update: updateDocsRemoveKey #711"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:04+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:58+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"admin","date":"2019-07-24T12:21:57+02:00","reason":"update"},{"user":"admin","date":"2019-07-24T12:22:25+02:00","reason":"update"},{"user":"admin","date":"2019-07-24T12:22:36+02:00","reason":"update"},{"user":"admin","date":"2019-08-15T14:20:00+02:00","reason":"Database update: updateDocsForKeyValue #418"}],"mon":{"year_2015":{"building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":350,"building_general_total_gross_floor_area":6800,"building_general_total_heated_net_room_area":6500,"building_general_total_cooled_net_room_area":6500},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","new_building_value":2011},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.5},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.25,"new_building_value":0.12},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.15},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.3,"new_building_value":0.12},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":0.8},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":0.4}],"ict":"Building Energy Management System"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":105000,"renewable_energy_financial":{"total_investment_costs":201600,"total_operating_costs":4000,"total_grants":60000,"feed_tariff_calculated":"7.4136125654450264","feed_tariff":7}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":62,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.3,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2011},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"443300"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":125000,"reference":"75000","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":2500,"reference":"3500","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":40000,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":31500,"reference":"17000","calculation":"31031.000000000004"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":28,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.15,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.05,"reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"127400"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":75000,"reference":"130000","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":1500,"reference":"2600","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":25000,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":1386,"reference":"5000","calculation":"6370"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":0,"calculation":"-16.970725498515062"}]}],"grid_electricity_price":"0.22","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":104,"savings":-3,"reference":"101","calculation":"103.95384615384616"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":55,"savings":-3,"reference":"52"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":19.6,"savings":-0.6,"reference":"19"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":13.2,"savings":-0.2,"reference":"13"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":16.2,"savings":-0.2,"reference":"16"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"31051.8","demonstration_building_overridden":80542,"savings_programmed":"58558","savings_programmed_overridden":139100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"127.35384615384615","demonstration_building_overridden":64,"savings_programmed":"66","savings_programmed_overridden":130},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"15.539440580139114","demonstration_building_overridden":13.4,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":12862500,"new_building_value":14000000,"calculation":"401600"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":1140000,"calculation":"401600"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","national_requirements":115000,"new_building_value":100000,"calculation":"8000"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":300000,"calculation":"125000"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":51000,"new_building_value":77686,"calculation":"37401"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":400,"new_building_social_jobs_created":5}}},"year_2016":{"building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":350,"building_general_total_gross_floor_area":6800,"building_general_total_heated_net_room_area":6500,"building_general_total_cooled_net_room_area":6500},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","new_building_value":2011},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.5},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.25,"new_building_value":0.12},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.15},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.3,"new_building_value":0.12},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":0.8},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":0.4}],"ict":"Building Energy Management System"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":95000,"renewable_energy_financial":{"total_investment_costs":201600,"total_operating_costs":0,"total_grants":60000,"feed_tariff_calculated":"6.77511961722488","feed_tariff":7}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":62,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.3,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"399100"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":125000,"reference":"75000","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":2500,"reference":"3500","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":40000,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":31500,"reference":"17000","calculation":"27937.000000000004"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":2.5}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":28,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.15,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.05,"reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"131300"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":75000,"reference":"130000","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":1500,"reference":"2600","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":25000,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":1386,"reference":"5000","calculation":"6565"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":0,"calculation":"-16.970725498515062"}]}],"grid_electricity_price":"0.22","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":102,"savings":-1,"reference":"101","calculation":"96.21538461538462"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":49,"savings":3,"reference":"52"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":20,"savings":-1,"reference":"19"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":12,"savings":1,"reference":"13"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":21,"savings":-5,"reference":"16"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"28420.6","demonstration_building_overridden":91353,"savings_programmed":"47747","savings_programmed_overridden":139100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"117.66538461538461","demonstration_building_overridden":73,"savings_programmed":"57","savings_programmed_overridden":130},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"15.190278221937959","demonstration_building_overridden":12.5,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":12862500,"new_building_value":14000000,"calculation":"401600"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":1140000,"calculation":"401600"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","national_requirements":115000,"new_building_value":100000,"calculation":"4000"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":300000,"calculation":"125000"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":51000,"new_building_value":77686,"calculation":"34502"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":400,"new_building_social_jobs_created":5}}}}}

SRT ID

cluster:next-buildings-site-amsterdam_new-building-s-_brede-school