Skip to main content
Smart Cities Marketplace
Scalable cities

One academic building

SRT Data

{"_id":"cluster:need4b-site-istanbul-_new-building-s-_one-academic-building","_rev":"274-0eba66f5e98aeff5f9f6350213a28cb4","document_type":"cluster","scis_id":"need4b-site-istanbul-_new-building-s-_one-academic-building","cluster_type":"new-building-s-","building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":1585,"building_general_total_gross_floor_area":17756,"building_general_total_heated_net_room_area":15093,"building_general_total_cooled_net_room_area":15093},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.248},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.302},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.568},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.4,"new_building_value":1.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":0.6}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":129000,"renewable_energy_financial":{"total_investment_costs":193050,"total_operating_costs":6.44,"total_grants":0,"feed_tariff_calculated":"30.572201388536968"}}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.36,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"356669"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":24838,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":29.95,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":29.95,"calculation":"42158.2758"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":4.2}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.36,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"750592"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":29.95,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":29.95,"calculation":"88719.9744"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.02377,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":23.5,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":23.5},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.36,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":115977,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":29.95,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":29.95},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.049","demo_site_fuel_cost":"0.018"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":53,"savings":19,"reference":"72","calculation":"81.90956072351422"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":0,"calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"10.43468976211334"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":6423040,"new_building_value":6956521.74,"calculation":"375295"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":301485,"calculation":"375295"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","new_building_value":70163,"calculation":"119.79"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":954087,"calculation":"41430"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":148719.82,"calculation":"130878.25020000001"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":38},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":2}],"social":{"new_building_social_citizens_involved":1585,"new_building_social_jobs_created":150}},"monitoring_data":{"monitoring_object":[{"monitoring_general_data":{"monitoring_general_data_year":"2014"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":152800,"renewable_energy_financial":[]}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.02377,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":4750,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":99502},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":49751,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2015"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":124500,"renewable_energy_financial":{"total_operating_costs":2.74}}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.11212,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":901872},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":10.96},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":10.96},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.11212,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":13.7},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":13.7},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.02398,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":164.38},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":164.38},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.11212,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":115977},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":27.4},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":27.4},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":60,"savings":228,"reference":"288"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":26,"calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":22,"calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":12,"calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"2085"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":236000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2016"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":125100,"renewable_energy_financial":{"total_operating_costs":2.8}}],"detailed_ec":[{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.02749,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":625188.76},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":153.42,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":153.42,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.12855,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":44034.88},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":12.87,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":12.87,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.12855,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":0},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":10.42,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":10.42,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.12855,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":69425.96},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":115977,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":27.4,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":27.4},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":49,"savings":83,"reference":"132","calculation":"57.22849002849003"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":18,"savings":83,"reference":"101","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":25,"savings":83,"reference":"108","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":8,"savings":83,"reference":"91","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"2085","demonstration_building_overridden":89015},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"738649.6","demonstration_building_overridden":57},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.000009596080408247957","demonstration_building_overridden":134}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":210000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2017"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":121000,"renewable_energy_financial":{"total_operating_costs":2.74}}],"detailed_ec":[{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.017985,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":459702.84},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":150.68,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":150.68,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.084232,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":50782.16},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":25.21,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":25.21,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.084232,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":0},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":10.14,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":10.14,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.084232,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":46520.72},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":11.24,"calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":11.24,"calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":41,"savings":85,"reference":"126","calculation":"44.921865765586695"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":17,"savings":85,"reference":"102","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":20,"savings":85,"reference":"105","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":20,"savings":85,"reference":"105","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"2085","demonstration_building_overridden":63318},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"557005.72","demonstration_building_overridden":41},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.00001182432724215601","demonstration_building_overridden":89}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":205000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"revisions":[{"user":"rudy.rooth","date":"2018-08-02T09:34:59+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:02+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:53+00:00","reason":"Database update: _update_481_ReplaceSelectCommas #481"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:53+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:43:33+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-24T13:48:48+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:14+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:13+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T09:41:55+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:38+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-14T09:55:01+00:00","reason":"Database update: updateDocsForKeyValue #655"},{"user":"rudy.rooth","date":"2019-02-14T13:55:26+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-14T14:04:07+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-14T14:17:49+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-14T14:28:18+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-14T14:35:04+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:28+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:15:47+01:00","reason":"Database update: updateDocsForKeyValue #703"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:04+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:58+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"admin","date":"2019-08-15T14:20:00+02:00","reason":"Database update: updateDocsForKeyValue #418"},{"user":"admin","date":"2019-08-15T14:25:58+02:00","reason":"Database update: updateDocsForKeyValue #836"},{"user":"rudy.rooth","date":"2020-10-09T14:52:56+01:00","reason":"update"}],"mon":{"year_2014":{"building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":1585,"building_general_total_gross_floor_area":17756,"building_general_total_heated_net_room_area":15093,"building_general_total_cooled_net_room_area":15093},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.248},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.302},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.568},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.4,"new_building_value":1.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":0.6}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":152800,"renewable_energy_financial":{"total_investment_costs":193050,"total_operating_costs":6.44,"total_grants":0,"feed_tariff_calculated":"25.80620150893759"}}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":24838,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":29.95,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":29.95},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":4.2}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":29.95,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":29.95},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.02377,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":4750,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1182,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":99502,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":49751,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.049","demo_site_fuel_cost":"0.018"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":53,"savings":19,"reference":"72","calculation":"10.123898495991519"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":0,"calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"100"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":6423040,"new_building_value":6956521.74,"calculation":"358820"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":301485,"calculation":"358820"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","new_building_value":70163},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":954087,"calculation":"86431"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":148719.82,"calculation":"0"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":38},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":2}],"social":{"new_building_social_citizens_involved":1585,"new_building_social_jobs_created":150}}},"year_2017":{"building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":1585,"building_general_total_gross_floor_area":17756,"building_general_total_heated_net_room_area":15093,"building_general_total_cooled_net_room_area":15093},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.248},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.302},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.568},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.4,"new_building_value":1.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":0.6}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":121000,"renewable_energy_financial":{"total_investment_costs":193050,"total_operating_costs":2.74,"total_grants":0,"feed_tariff_calculated":"32.575351064583735"}}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.084,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"0"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":24838,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":10.14,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"0"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":4.2}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.084,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"46520"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":11.24,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":15965,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"3907.6800000000003"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.018,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"459702"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":150.68,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"8274.635999999999"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.084,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"50782.16"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":115977,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":25.21,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"4265.701440000001"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.049","demo_site_fuel_cost":"0.018"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":41,"savings":85,"reference":"126","calculation":"44.92176240641357"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":17,"savings":85,"reference":"102","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":20,"savings":85,"reference":"105","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":20,"savings":85,"reference":"105","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"167605.70072","demonstration_building_overridden":63318},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"44.92176240641357","demonstration_building_overridden":41},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"17.846498168978787"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":6423040,"new_building_value":6956521.74,"calculation":"375295"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":301485,"calculation":"375295"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","new_building_value":70163,"calculation":"200.01000000000002"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":954087,"calculation":"25465"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":205000,"calculation":"16448.01744"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":38},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":2}],"social":{"new_building_social_citizens_involved":1585,"new_building_social_jobs_created":150}}},"year_2016":{"building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1,"building_general_number_year_completion":2014},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":1585,"building_general_total_gross_floor_area":17756,"building_general_total_heated_net_room_area":15093,"building_general_total_cooled_net_room_area":15093},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.248},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.302},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.568},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.4,"new_building_value":1.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":0.6}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":125100,"renewable_energy_financial":{"total_investment_costs":193050,"total_operating_costs":2.8,"total_grants":0,"feed_tariff_calculated":"31.50756475330907"}}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.128,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":24838},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":10.42},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":4.2}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.128,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":44034},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":31930},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":12.87},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":15965},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"5636.352"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.0275,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":625188},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":153},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":4750},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"17192.670000000002"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.128,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":69425},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":115977},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":27.4},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"8886.4"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.049","demo_site_fuel_cost":"0.018"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":49,"savings":83,"reference":132},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":18,"savings":83,"reference":101},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":25,"savings":83,"reference":108},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":0},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":8,"savings":83,"reference":91}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":89015},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":57},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_overridden":13.4}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":6423040,"new_building_value":6956521.74,"calculation":"375295"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":301485,"calculation":"375295"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","new_building_value":70163,"calculation":"206.49"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":954087,"calculation":"20715"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":210000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":38},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":2}],"social":{"new_building_social_citizens_involved":1585,"new_building_social_jobs_created":150}}},"year_2015":{"building_general":{"building_general_number_buildings":"1","building_general_number_monitored_buildings":"1","building_general_number_year_completion":"2014"},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_occupants":1585,"building_general_total_gross_floor_area":17756,"building_general_total_heated_net_room_area":15093,"building_general_total_cooled_net_room_area":15093},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2012,"new_building_value":2016},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.248},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.302},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.568},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.4,"new_building_value":1.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":0.6}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":124500,"renewable_energy_financial":{"total_investment_costs":193050,"total_operating_costs":6.44,"total_grants":0,"feed_tariff_calculated":"31.678388463520214"}}],"detailed_ec":[{"technology":"other please specify","technology_other":"Ait-ground-air heat exchanger","ec_name":"\u2018Green\u2019 electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1122,"reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"901872"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":24838,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":10.96,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"101190.03839999999"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":4.2}]},{"technology":"other please specify","technology_other":"VRV System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1122,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":29.95,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":31930,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":29.95},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and cooling and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":234,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.024,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":164,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":9500,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":164},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"other please specify","technology_other":"Conventional HVAC System","ec_name":"Electricity","building_service":"heating and cooling","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":617,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2015},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.1122,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":115977,"calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":27.4,"calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":0,"calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":27.4},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.049","demo_site_fuel_cost":"0.018"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":60,"savings":228,"reference":"288","calculation":"68.00318028225006"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":26,"calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":22,"calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":12,"calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"12.130104874256117"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":6423040,"new_building_value":6956521.74,"calculation":"375295"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":301485,"calculation":"375295"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac","new_building_value":70163,"calculation":"238.75"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":954087,"calculation":"41430"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":236000,"calculation":"101190.03839999999"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":38},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":2}],"social":{"new_building_social_citizens_involved":1585,"new_building_social_jobs_created":150}}}}}

SRT ID

cluster:need4b-site-istanbul-_new-building-s-_one-academic-building