Skip to main content
Smart Cities Marketplace
Scalable cities

Measure 1.1 Energy efficient refurbishment of the building - Valla Torg, 3 residential buildings 2A/3B/7G

SRT Data

{"_id":"cluster:growsmarter-site-stockholm-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---valla-torg-3-residential-buildings-2a-3b-7g","_rev":"25-80e972e3866fb8e5adeacc502bc1d415","document_type":"cluster","scis_id":"growsmarter-site-stockholm-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---valla-torg-3-residential-buildings-2a-3b-7g","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":3,"building_general_number_monitored_buildings":1,"building_general_number_year_completion":1961},"building_general_technical":{"building_general_building_type":"residential","old_building_general_total_heated_net_room_area":5401.5,"building_general_total_heated_net_room_area":5651},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.42,"old_building_value":0.76},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","new_building_value":0.08,"old_building_value":0.18},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","new_building_value":0.22,"old_building_value":0.49},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","new_building_value":0.4,"old_building_value":0.4},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":0.7,"old_building_value":2.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":60,"old_building_value":79}],"ict":"Building Energy Management System,Demand Response","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":7247,"renewable_energy_financial":{}}],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":127,"savings":0,"reference":127,"old_building_value":127},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":120,"savings":0,"reference":120,"old_building_value":120},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":7,"savings":0,"reference":7,"old_building_value":7}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":65721,"demonstration_building_overridden":65721,"savings_programmed":"0","savings_programmed_overridden":65721},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"revisions":[{"user":"Sigrid Granstrom","date":"2019-11-13T09:20:58+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T09:21:27+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T11:14:47+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T11:15:24+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T11:17:27+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T11:18:57+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:26:52+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:27:58+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:30:00+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:32:03+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:34:08+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:54:04+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-16T10:11:35+00:00","reason":"update"}],"mon":{"year_2019":{"building_general":{"building_general_number_buildings":3,"building_general_number_monitored_buildings":1,"building_general_number_year_completion":1961},"building_general_technical":{"building_general_building_type":"residential","old_building_general_total_heated_net_room_area":5401.5,"building_general_total_heated_net_room_area":5651},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.42,"old_building_value":0.76},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.13,"new_building_value":0.08,"old_building_value":0.18},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.18,"new_building_value":0.22,"old_building_value":0.49},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.15,"new_building_value":0.4,"old_building_value":0.4},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":1.2,"new_building_value":0.7,"old_building_value":2.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":60,"old_building_value":79}],"ict":"Building Energy Management System,Demand Response","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":7247,"renewable_energy_financial":{}}],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":51.2,"savings":75.8,"reference":127,"old_building_value":127},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":24,"savings":96,"reference":120,"old_building_value":120},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":29.3,"savings":-22.3,"reference":7,"old_building_value":7}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":22900,"demonstration_building_overridden":22900,"savings_programmed":"42821","savings_programmed_overridden":65721},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":0,"new_building_value":602840},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","national_requirements":0,"new_building_value":0},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":357760},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_jobs_created":4}}}}}

SRT ID

cluster:growsmarter-site-stockholm-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---valla-torg-3-residential-buildings-2a-3b-7g