Skip to main content
Smart Cities Marketplace
Scalable cities

Measure 1.1 Energy efficient refurbishment of the building - Valla Torg, 2 residential buildings 5E/8H

SRT Data

{"_id":"cluster:growsmarter-site-stockholm-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---valla-torg-2-residential-buildings-5e-8h","_rev":"25-021b0cb2e9fd8ddc91636d34b4cd35c2","document_type":"cluster","scis_id":"growsmarter-site-stockholm-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---valla-torg-2-residential-buildings-5e-8h","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":2,"building_general_number_monitored_buildings":1},"building_general_technical":{"building_general_building_type":"residential","old_building_general_total_heated_net_room_area":4571,"building_general_total_heated_net_room_area":4626},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.42,"old_building_value":0.76},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","new_building_value":0.08,"old_building_value":0.18},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","new_building_value":0.22,"old_building_value":0.49},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","new_building_value":0.4,"old_building_value":0.4},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":0.7,"old_building_value":2.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":60,"old_building_value":79}],"ict":"Building Energy Management System,Demand Response","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":21161,"renewable_energy_financial":{}}],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"544850"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":126157},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"6307.85"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"heat pump: absorption","ec_name":"\u2018Green\u2019 electricity","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"heat pump: absorption","ec_name":"\u2018Green\u2019 electricity","building_service":"DHW (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":125,"savings":0,"reference":125,"old_building_value":125},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":119,"savings":0,"reference":119,"old_building_value":119},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":6,"savings":0,"reference":6,"old_building_value":6}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":50700,"demonstration_building_overridden":50700,"savings_programmed":"0","savings_programmed_overridden":50700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"6307.85"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"revisions":[{"user":"Sigrid Granstrom","date":"2019-11-13T09:22:37+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T11:19:49+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T11:31:35+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:49:16+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:52:21+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2019-11-13T13:54:39+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-16T10:14:51+00:00","reason":"update"}],"mon":{"year_2019":{"building_general":{"building_general_number_buildings":2,"building_general_number_monitored_buildings":1},"building_general_technical":{"building_general_building_type":"residential","old_building_general_total_heated_net_room_area":4571,"building_general_total_heated_net_room_area":4626},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","new_building_value":0.42,"old_building_value":0.76},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.13,"new_building_value":0.08,"old_building_value":0.18},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.18,"new_building_value":0.22,"old_building_value":0.49},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.15,"new_building_value":0.4,"old_building_value":0.4},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":1.2,"new_building_value":0.7,"old_building_value":2.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":60,"old_building_value":79}],"ict":"Building Energy Management System,Demand Response","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":21161,"renewable_energy_financial":{}}],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"544850"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":126157},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"6307.85"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"heat pump: absorption","ec_name":"\u2018Green\u2019 electricity","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"heat pump: absorption","ec_name":"\u2018Green\u2019 electricity","building_service":"DHW (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"24","source":"Covenant of Mayors"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.01","source":"IINAS"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.21","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":55.2,"savings":69.8,"reference":125,"old_building_value":125},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":27.3,"savings":91.7,"reference":119,"old_building_value":119},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":27.6,"savings":-21.6,"reference":6,"old_building_value":6}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":18500,"demonstration_building_overridden":18500,"savings_programmed":"32200","savings_programmed_overridden":50700},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":0,"new_building_value":477938},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","national_requirements":0,"new_building_value":0},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":255296},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"6307.85"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_jobs_created":3}}}}}

SRT ID

cluster:growsmarter-site-stockholm-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---valla-torg-2-residential-buildings-5e-8h