Skip to main content
European Commission logo
Smart Cities Marketplace
Apply for technical assistance

Measure 1.1 Energy efficient refurbishment of the building - Ca l'Alier

SRT Data

{"_id":"cluster:growsmarter-site-barcelona-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---ca-l-alier","_rev":"15-60e23014136e517d06647a74da2f5c96","document_type":"cluster","scis_id":"growsmarter-site-barcelona-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---ca-l-alier","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","old_building_general_total_heated_net_room_area":2173,"building_general_total_heated_net_room_area":2100,"old_building_general_total_cooled_net_room_area":2173,"building_general_total_cooled_net_room_area":2100},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2018},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":1.27,"new_building_value":0.73,"old_building_value":3.68},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.41,"new_building_value":0.37,"old_building_value":6.67},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.73,"new_building_value":0.63,"old_building_value":2.21},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.5,"new_building_value":0.45,"old_building_value":0.56},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.81,"new_building_value":1.2,"old_building_value":5.7},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":0.35,"new_building_value":0.315,"old_building_value":0.85}],"ict":"Building Energy Management System"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":86074,"renewable_energy_financial":{}}],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":145,"savings":77,"reference":222,"old_building_value":222},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":30,"savings":20,"reference":50,"old_building_value":50},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":55,"savings":27,"reference":82,"old_building_value":82},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":60,"savings":30,"reference":90,"old_building_value":90}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":91130,"savings_programmed_overridden":91130},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":222,"demonstration_building_overridden":109.1,"savings_programmed":"131.9","savings_programmed_overridden":241},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":19.8,"savings_programmed_overridden":3.5}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"revisions":[{"user":"Sigrid Granstrom","date":"2020-01-23T10:06:38+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:10:34+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:12:27+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:13:53+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:16:47+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:19:09+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:31:16+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:49:07+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:50:58+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:51:21+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T10:59:47+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T11:02:57+00:00","reason":"update"},{"user":"Sigrid Granstrom","date":"2020-01-23T15:40:41+00:00","reason":"update"}],"mon":{"year_2018":{"building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","old_building_general_total_heated_net_room_area":2173,"building_general_total_heated_net_room_area":2100,"old_building_general_total_cooled_net_room_area":2173,"building_general_total_cooled_net_room_area":2100},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2018},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":1.27,"new_building_value":0.73,"old_building_value":3.68},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.41,"new_building_value":0.37,"old_building_value":6.67},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.73,"new_building_value":0.63,"old_building_value":2.21},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.5,"new_building_value":0.45,"old_building_value":0.56},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.81,"new_building_value":1.2,"old_building_value":5.7},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":0.35,"new_building_value":0.315,"old_building_value":0.85}],"ict":"Building Energy Management System"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":86074,"renewable_energy_financial":{}}],"old_detailed_ec":[],"detailed_ec":[],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":145,"savings":77,"reference":222,"old_building_value":222},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":30,"savings":20,"reference":50,"old_building_value":50},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":55,"savings":27,"reference":82,"old_building_value":82},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":60,"savings":30,"reference":90,"old_building_value":90}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":91130,"demonstration_building_overridden":51360,"savings_programmed":"39770","savings_programmed_overridden":91130},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":222,"demonstration_building_overridden":109.1,"savings_programmed":"131.9","savings_programmed_overridden":241},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":19.8,"savings_programmed_overridden":3.5}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","new_building_value":8214551},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","new_building_value":33886},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":5200,"new_building_social_jobs_created":80}}}}}

SRT ID

cluster:growsmarter-site-barcelona-_refurbished-building-s-_measure-1-1-energy-efficient-refurbishment-of-the-building---ca-l-alier