Skip to main content
European Commission logo
Smart Cities Marketplace
Apply for technical assistance

New distribution system (12 heat exchange substations at building level, variable flow pumping system, smart thermal energy meters, thermostat and cut-off valves at home level...)

SRT Data

{"_id":"cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-","_rev":"133-b931d63ce5713876b17bff12abef02db","document_type":"cluster","scis_id":"cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-","cluster_type":"dhc-extension","energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"existing network","energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":12238},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1488},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":15},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.0404},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":87},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":65},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":80},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":65},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"15174353"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"85"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":15174353},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":12898200},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":4628177.665},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":20637120.08}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"758717.65"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}},"revisions":[{"user":"rudy.rooth","date":"2018-12-05T14:17:21+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-01-30T07:25:04+00:00","reason":"Database update: _update_362_kpi_env_esi_no_m2 #362"},{"user":"alivas","date":"2019-05-07T13:52:14+02:00","reason":"update"},{"user":"alivas","date":"2019-05-07T13:55:13+02:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:02+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:56+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rudy.rooth","date":"2019-06-26T14:49:05+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T16:17:28+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T09:30:21+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T10:57:49+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-23T07:48:23+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-23T07:49:01+01:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:36:40+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:44:44+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:45:26+00:00","reason":"update"},{"user":"rudy.rooth","date":"2020-04-22T16:09:53+01:00","reason":"Renamed from 'cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level--rr' to 'cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-'"}],"mon":{"year_2017":{"energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"existing network","energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":12238},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1488},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":15},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.0404},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":87},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":65},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":80},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":65},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"10331160"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"85"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":15174353},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":12898200},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":3151003.8},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":14050377.6}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"516558"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}}},"year_2018":{"energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"existing network","energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":12238},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1488},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":15},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.0404},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":87},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":65},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":80},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":65},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"10958640"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"85"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":15174353},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":12898200},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":3342385.2},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":14903750.4}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"547932"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}}}}}

SRT ID

cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-