Skip to main content
Smart Cities Marketplace
Scalable cities

New distribution system (12 heat exchange substations at building level, variable flow pumping system, smart thermal energy meters, thermostat and cut-off valves at home level...)

SRT Data

{"_id":"cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-","_rev":"133-b931d63ce5713876b17bff12abef02db","document_type":"cluster","scis_id":"cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-","cluster_type":"dhc-extension","energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"existing network","energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":12238},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1488},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":15},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.0404},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":87},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":65},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":80},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":65},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"15174353"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"85"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":15174353},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":12898200},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":4628177.665},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":20637120.08}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"758717.65"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}},"revisions":[{"user":"rudy.rooth","date":"2018-12-05T14:17:21+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-01-30T07:25:04+00:00","reason":"Database update: _update_362_kpi_env_esi_no_m2 #362"},{"user":"alivas","date":"2019-05-07T13:52:14+02:00","reason":"update"},{"user":"alivas","date":"2019-05-07T13:55:13+02:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:02+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:56+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rudy.rooth","date":"2019-06-26T14:49:05+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T16:17:28+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T09:30:21+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T10:57:49+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-23T07:48:23+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-23T07:49:01+01:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:36:40+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:44:44+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:45:26+00:00","reason":"update"},{"user":"rudy.rooth","date":"2020-04-22T16:09:53+01:00","reason":"Renamed from 'cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level--rr' to 'cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-'"}],"mon":{"year_2017":{"energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"existing network","energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":12238},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1488},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":15},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.0404},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":87},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":65},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":80},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":65},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"10331160"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"85"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":15174353},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":12898200},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":3151003.8},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":14050377.6}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"516558"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}}},"year_2018":{"energy_systems_general":{"energy_systems_dhc_type":"District heating","energy_systems_dhc_construction":"existing network","energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_capacity","intervention_name":"maximum thermal heating capacity of network connection","unit":"kWth","value":12238},{"key":"maximal_cooling_capacity","intervention_name":"maximum thermal cooling capacity of network connection","unit":"kWth","value":0},{"key":"number_connections","intervention_name":"no. of connections i.e. households","value":1488},{"key":"network_losses","intervention_name":"network losses","unit":"%","value":15},{"key":"local_primary_energy_cooling","intervention_name":"local primary energy factor for district cooling","value":0},{"key":"local_primary_energy_heating","intervention_name":"local primary energy factor for district heating ","value":1.0404},{"key":"average_inlet_temperature_winter","intervention_name":"average inlet temperature in network during operation (winter)","unit":"\u00b0C","value":87},{"key":"average_return_temperature_winter","intervention_name":"average return temperature of the network during operation (winter)","unit":"\u00b0C","value":65},{"key":"average_inlet_temperature_summer","intervention_name":"average inlet temperature in network during operation (summer)","unit":"\u00b0C","value":80},{"key":"average_return_temperature_summer","intervention_name":"average return temperature of the network during operation (summer)","unit":"\u00b0C","value":65},{"key":"temperature_heating_energy_district_network","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Heat\/district heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"10958640"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"85"}]}]},"energy_systems_kpis":{"technical":[{"key":"subtotal_energy_fedin_network_heating","kpi_name":"Subtotal amount of energy fed into the network (heating)","unit":"kWh\/a","value":15174353},{"key":"subtotal_energy_extracted_network_heating","kpi_name":"Subtotal amount of energy extracted from the network (heating)","unit":"kWh\/a","value":12898200},{"key":"subtotal_energy_fedin_network_cooling","kpi_name":"Subtotal amount of energy fed into the network (cooling)","unit":"kWh\/a","value":0},{"key":"subtotal_energy_extracted_network_cooling","kpi_name":"Subtotal amount of energy extracted from the network (cooling)","unit":"kWh\/a","value":0}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":3342385.2},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":14903750.4}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Heat\/district heat","kpi_name":"Total energy cost Heat\/district heat","unit":"\u20ac\/a","calculation":"547932"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}}}}}

SRT ID

cluster:cityfied-site-laguna-de-duero_dhc-extension_new-distribution-system-12-heat-exchange-substations-at-building-level-variable-flow-pumping-system-smart-thermal-energy-meters-thermostat-and-cut-off-valves-at-home-level-