SRT Data
{"_id":"cluster:celsius-site-rotterdam-_thermal-storage_1-thermal-storage---rotterdam-heat-hub","_rev":"214-50c9b69bdde084c7250f0868f5505b13","document_type":"cluster","scis_id":"celsius-site-rotterdam-_thermal-storage_1-thermal-storage---rotterdam-heat-hub","cluster_type":"thermal-storage","energy_systems_general":{"energy_systems_thermal_storage_technology_supply":"district heating (DH) network","energy_systems_thermal_storage_ec":"Waste heat","energy_systems_year_completion":"2013"},"energy_systems_interventions":{"interventions":[{"key":"colume_storage","intervention_name":"volume of storage","unit":"m\u00b3"},{"key":"installed_capacity","intervention_name":"installed capacity","unit":"kWh"},{"key":"temperature_fluid_feedin_storage","intervention_name":"set temperature of fluid at feed-in in storage","unit":"\u00b0C","value":100},{"key":"storage_power_storage","intervention_name":"Storage power","unit":"MW"},{"key":"extraction_power_storage","intervention_name":"Extraction power","unit":"MW"},{"key":"temperature_fluid_return_storage","intervention_name":"set return temperature of fluid from storage","unit":"\u00b0C","value":60}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total amount of heating energy fed into the thermal storage","unit":"kWh\/a","value":4000000},{"key":"total_energy_generation_cooling","kpi_name":"Total amount of cooling energy fed into the thermal storage","unit":"kWh\/a"},{"key":"total_energy_extracted_heating","kpi_name":"Total amount of heating energy extracted from the thermal storage","unit":"kWh\/a","value":4000000},{"key":"total_energy_extracted_cooling","kpi_name":"Total amount of cooling energy extracted from the thermal storage","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","reference_system":2200000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","reference_system":7700000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":1046292},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":523146},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":12.5},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"revisions":[{"user":"rudy.rooth","date":"2019-02-19T15:11:18+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T15:12:42+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T15:15:47+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T15:17:42+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T15:19:54+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-28T12:44:52+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-28T12:45:05+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-28T12:45:19+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:05:45+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:06:59+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:07:37+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:08:08+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:56+01:00","reason":"Database update: updateDocsForKeyValue #773"}],"mon":{"year_2015":{"energy_systems_general":{"energy_systems_thermal_storage_type":"daily storage","energy_systems_thermal_storage_technology":"aquifer storage","energy_systems_thermal_storage_technology_supply":"district heating (DH) network","energy_systems_thermal_storage_ec":"Waste heat","energy_systems_year_completion":"2013"},"energy_systems_interventions":{"interventions":[{"key":"colume_storage","intervention_name":"volume of storage","unit":"m\u00b3"},{"key":"installed_capacity","intervention_name":"installed capacity","unit":"kWh"},{"key":"temperature_fluid_feedin_storage","intervention_name":"set temperature of fluid at feed-in in storage","unit":"\u00b0C","value":100},{"key":"storage_power_storage","intervention_name":"Storage power","unit":"MW"},{"key":"extraction_power_storage","intervention_name":"Extraction power","unit":"MW"},{"key":"temperature_fluid_return_storage","intervention_name":"set return temperature of fluid from storage","unit":"\u00b0C","value":60}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total amount of heating energy fed into the thermal storage","unit":"kWh\/a","value":3479000},{"key":"total_energy_generation_cooling","kpi_name":"Total amount of cooling energy fed into the thermal storage","unit":"kWh\/a"},{"key":"total_energy_extracted_heating","kpi_name":"Total amount of heating energy extracted from the thermal storage","unit":"kWh\/a","value":3769000},{"key":"total_energy_extracted_cooling","kpi_name":"Total amount of cooling energy extracted from the thermal storage","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":0,"savings_programmed":"801000","reference_system":801000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_overridden":3774000,"savings_programmed":"4110000","reference_system":7884000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":1046292},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":523146},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":12.5},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}},"year_2016":{"energy_systems_general":{"energy_systems_thermal_storage_type":"daily storage","energy_systems_thermal_storage_technology":"aquifer storage","energy_systems_thermal_storage_technology_supply":"district heating (DH) network","energy_systems_thermal_storage_ec":"Waste heat","energy_systems_year_completion":"2013"},"energy_systems_interventions":{"interventions":[{"key":"colume_storage","intervention_name":"volume of storage","unit":"m\u00b3"},{"key":"installed_capacity","intervention_name":"installed capacity","unit":"kWh"},{"key":"temperature_fluid_feedin_storage","intervention_name":"set temperature of fluid at feed-in in storage","unit":"\u00b0C","value":100},{"key":"storage_power_storage","intervention_name":"Storage power","unit":"MW"},{"key":"extraction_power_storage","intervention_name":"Extraction power","unit":"MW"},{"key":"temperature_fluid_return_storage","intervention_name":"set return temperature of fluid from storage","unit":"\u00b0C","value":60}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total amount of heating energy fed into the thermal storage","unit":"kWh\/a","value":1676000},{"key":"total_energy_generation_cooling","kpi_name":"Total amount of cooling energy fed into the thermal storage","unit":"kWh\/a"},{"key":"total_energy_extracted_heating","kpi_name":"Total amount of heating energy extracted from the thermal storage","unit":"kWh\/a","value":1805000},{"key":"total_energy_extracted_cooling","kpi_name":"Total amount of cooling energy extracted from the thermal storage","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":0,"savings_programmed":"384000","reference_system":384000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_overridden":3333000,"savings_programmed":"1950000","reference_system":5283000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":1046292},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":523146},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":12.5},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}},"year_2017":{"energy_systems_general":{"energy_systems_thermal_storage_type":"daily storage","energy_systems_thermal_storage_technology":"aquifer storage","energy_systems_thermal_storage_technology_supply":"district heating (DH) network","energy_systems_thermal_storage_ec":"Waste heat","energy_systems_year_completion":"2013"},"energy_systems_interventions":{"interventions":[{"key":"colume_storage","intervention_name":"volume of storage","unit":"m\u00b3"},{"key":"installed_capacity","intervention_name":"installed capacity","unit":"kWh"},{"key":"temperature_fluid_feedin_storage","intervention_name":"set temperature of fluid at feed-in in storage","unit":"\u00b0C","value":100},{"key":"storage_power_storage","intervention_name":"Storage power","unit":"MW"},{"key":"extraction_power_storage","intervention_name":"Extraction power","unit":"MW"},{"key":"temperature_fluid_return_storage","intervention_name":"set return temperature of fluid from storage","unit":"\u00b0C","value":60}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total amount of heating energy fed into the thermal storage","unit":"kWh\/a","value":1082000},{"key":"total_energy_generation_cooling","kpi_name":"Total amount of cooling energy fed into the thermal storage","unit":"kWh\/a"},{"key":"total_energy_extracted_heating","kpi_name":"Total amount of heating energy extracted from the thermal storage","unit":"kWh\/a","value":921000},{"key":"total_energy_extracted_cooling","kpi_name":"Total amount of cooling energy extracted from the thermal storage","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_overridden":0,"savings_programmed":"196000","reference_system":196000},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_overridden":3691000,"savings_programmed":"970000","reference_system":4661000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":1046292},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":523146},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":12.5},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}}}}
SRT ID
cluster:celsius-site-rotterdam-_thermal-storage_1-thermal-storage---rotterdam-heat-hub