SRT Data
{"_id":"cluster:celsius-site-cologne_waste-heat_heat-recovery-from-sewage-network---wahn-site","_rev":"206-b2542800191ff6dd400a33fad200c64f","document_type":"cluster","scis_id":"celsius-site-cologne_waste-heat_heat-recovery-from-sewage-network---wahn-site","cluster_type":"waste-heat","energy_systems_general":{"energy_systems_source_waste_heat":"Underground Infrastructure","energy_systems_source_waste_heat_industry":"Other industry","energy_systems_source_waste_heat_industry_other":"Sewage network","energy_systems_year_completion":"2015"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_network_connection","intervention_name":"maximum thermal network connection power ","unit":"kWth","value":200},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":60},{"key":"heating_temperature_input","intervention_name":"set input heat temperature","unit":"\u00b0C","value":15}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Waste heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"0","source":"SCIS estimation for pure waste heat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1","source":"SCIS estimation for pure waste heat"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.03","source":"Ecofys"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1000000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"The yearly amount of thermal energy produced\/provided by the new system","unit":"kWh\/a","value":1000000}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"reference_system":12},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":1000000,"reference_system":1445500}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":530000,"reference_system":20000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":265000,"reference_system":0},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":98000},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":56000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":19},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Waste heat","kpi_name":"Total energy cost Waste heat","unit":"\u20ac\/a","value":0,"calculation":"30000"}],"social":{"new_building_social_citizens_involved":1310,"new_building_floor_area":20650}},"revisions":[{"user":"rudy.rooth","date":"2019-02-19T09:22:04+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T09:27:31+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T09:30:22+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T09:33:40+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T09:36:51+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-19T09:41:55+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-28T15:20:44+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:05:45+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:02+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:56+01:00","reason":"Database update: updateDocsForKeyValue #773"}],"mon":{"year_2015":{"energy_systems_general":{"energy_systems_source_waste_heat":"Underground Infrastructure","energy_systems_source_waste_heat_industry":"Other industry","energy_systems_source_waste_heat_industry_other":"Sewage network","energy_systems_year_completion":"2015"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_network_connection","intervention_name":"maximum thermal network connection power ","unit":"kWth","value":200},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":60},{"key":"heating_temperature_input","intervention_name":"set input heat temperature","unit":"\u00b0C","value":15}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Waste heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"0","source":"SCIS estimation for pure waste heat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1","source":"SCIS estimation for pure waste heat"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0,"reference":"0.03","source":"Ecofys"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1109000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"The yearly amount of thermal energy produced\/provided by the new system","unit":"kWh\/a","value":1109000}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"demonstration_building_overridden":12,"reference_system":13},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":1109000,"demonstration_building_overridden":1197700,"reference_system":1445500}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":530000,"reference_system":20000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":265000,"reference_system":0},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":108000},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":56000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":14},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Waste heat","kpi_name":"Total energy cost Waste heat","unit":"\u20ac\/a","value":0,"calculation":"33270"}],"social":{"new_building_social_citizens_involved":1310,"new_building_floor_area":20650}}},"year_2016":{"energy_systems_general":{"energy_systems_source_waste_heat":"Underground Infrastructure","energy_systems_source_waste_heat_industry":"Other industry","energy_systems_source_waste_heat_industry_other":"Sewage network","energy_systems_year_completion":"2015"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_network_connection","intervention_name":"maximum thermal network connection power ","unit":"kWth","value":200},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":60},{"key":"heating_temperature_input","intervention_name":"set input heat temperature","unit":"\u00b0C","value":15}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Waste heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"0","source":"SCIS estimation for pure waste heat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1","source":"SCIS estimation for pure waste heat"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0,"reference":"0.03","source":"Ecofys"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1015000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"The yearly amount of thermal energy produced\/provided by the new system","unit":"kWh\/a","value":1015000}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"demonstration_building_overridden":10,"reference_system":12},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":1015000,"demonstration_building_overridden":1011850,"reference_system":1362900}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":530000,"reference_system":20000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":265000,"reference_system":0},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":10000},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":66000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":27},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Waste heat","kpi_name":"Total energy cost Waste heat","unit":"\u20ac\/a","value":0,"calculation":"30450"}],"social":{"new_building_social_citizens_involved":1310,"new_building_floor_area":20650}}},"year_2017":{"energy_systems_general":{"energy_systems_source_waste_heat":"Underground Infrastructure","energy_systems_source_waste_heat_industry":"Other industry","energy_systems_source_waste_heat_industry_other":"Sewage network","energy_systems_year_completion":"2015"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_network_connection","intervention_name":"maximum thermal network connection power ","unit":"kWth","value":200},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":60},{"key":"heating_temperature_input","intervention_name":"set input heat temperature","unit":"\u00b0C","value":15}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Waste heat","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"0","source":"SCIS estimation for pure waste heat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1","source":"SCIS estimation for pure waste heat"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0,"reference":"0.03","source":"Ecofys"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1183000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"The yearly amount of thermal energy produced\/provided by the new system","unit":"kWh\/a","value":1183000}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":0,"demonstration_building_overridden":9,"savings_programmed":"5","reference_system":14},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":1183000,"demonstration_building_overridden":970550,"savings_programmed":"640150","reference_system":1610700}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":530000,"reference_system":20000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":265000,"reference_system":0},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":108000},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":56000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","value":14},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Waste heat","kpi_name":"Total energy cost Waste heat","unit":"\u20ac\/a","value":0,"calculation":"35490"}],"social":{"new_building_social_citizens_involved":1310,"new_building_floor_area":20650}}}}}
SRT ID
cluster:celsius-site-cologne_waste-heat_heat-recovery-from-sewage-network---wahn-site