Skip to main content
Smart Cities Marketplace
Scalable cities

Arlequin 40 and 50 : 2 buildings

SRT Data

{"_id":"cluster:zenn-site-grenoble-_refurbished-building-s-_arlequin-40-and-50-2-buildings","_rev":"217-d3b7412f3d268f04807b41c149056a67","document_type":"cluster","scis_id":"zenn-site-grenoble-_refurbished-building-s-_arlequin-40-and-50-2-buildings","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":"2","building_general_number_monitored_buildings":"2","building_general_number_year_completion":"1975"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":254,"building_general_number_inhabitants":550,"building_general_number_occupants":600,"building_general_total_gross_floor_area":22173,"old_building_general_total_heated_net_room_area":21400,"building_general_total_heated_net_room_area":21400},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2007,"new_building_value":2016,"old_building_value":1975},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":1.5,"new_building_value":0.94,"old_building_value":1.9},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.28,"new_building_value":0.12,"old_building_value":2.1},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.45,"new_building_value":0.27,"old_building_value":1.4},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.36,"new_building_value":0.25,"old_building_value":0.25},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.6,"new_building_value":1.4,"old_building_value":2.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":40,"new_building_value":47,"old_building_value":40}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":142000,"renewable_energy_financial":{"total_investment_costs":243600,"total_operating_costs":6000,"total_grants":86500,"feed_tariff_calculated":"6.682945090098521"}}],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":141,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0.6,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy cost","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total Investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":45,"savings":-5,"reference":"40","old_building_value":110},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":20,"savings":10,"reference":"30","old_building_value":30},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":3.3,"savings":0.4,"reference":"3.7","old_building_value":4}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"monitoring_data":{"refurbished_monitoring_object":[{"monitoring_general_data":{"monitoring_general_data_year":"2017"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":142000,"renewable_energy_financial":{"total_operating_costs":6000}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":141,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.08,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total Investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/kWh"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":101.99,"savings":50,"old_building":"203.99"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":52.6,"savings":67,"old_building":"137"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"old_building":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":44,"savings":28,"old_building":"60"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":5.4,"savings":0,"old_building":"5.4"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building":510604,"demonstration_building_overridden":166920},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building":130,"demonstration_building_overridden":68},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building":50,"demonstration_building_overridden":92.93}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":191},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","reference":18},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"revisions":[{"user":"rudy.rooth","date":"2018-08-01T11:02:28+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:03+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:56+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-11T10:42:35+00:00","reason":"Database update: _update_579_insert_row_total_operating_cost #579: inject row total_operating_costs"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:16+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:14+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T11:12:49+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-11T09:46:15+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:39+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:29+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:18:09+01:00","reason":"Database update: updateDocsRemoveKey #711"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:07+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:31:03+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"admin","date":"2019-07-24T12:30:37+02:00","reason":"update"},{"user":"admin","date":"2019-07-24T12:31:23+02:00","reason":"update"},{"user":"admin","date":"2019-08-15T14:25:59+02:00","reason":"Database update: updateDocsForKeyValue #836"}],"mon":{"year_2017":{"building_general":{"building_general_number_buildings":"2","building_general_number_monitored_buildings":"2","building_general_number_year_completion":"1975"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":254,"building_general_number_inhabitants":550,"building_general_number_occupants":600,"building_general_total_gross_floor_area":22173,"old_building_general_total_heated_net_room_area":21400,"building_general_total_heated_net_room_area":21400},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2007,"new_building_value":2016,"old_building_value":1975},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":1.5,"new_building_value":0.94,"old_building_value":1.9},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.28,"new_building_value":0.12,"old_building_value":2.1},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.45,"new_building_value":0.27,"old_building_value":1.4},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.36,"new_building_value":0.25,"old_building_value":0.25},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.6,"new_building_value":1.4,"old_building_value":2.6},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":40,"new_building_value":47,"old_building_value":40}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic - building integrated","installed_electricity":142000,"renewable_energy_financial":{"total_investment_costs":243600,"total_operating_costs":6000,"total_grants":86500,"feed_tariff_calculated":"6.682945090098521"}}],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":141,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0.6,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":141,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy cost","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.08,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total Investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2078","demo_site_fuel_cost":"0.0664"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":102,"savings":50,"reference":"152","old_building_value":204},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":53,"savings":67,"reference":"120","old_building_value":137},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","old_building_value":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":44,"savings":28,"reference":"72","old_building_value":60},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":5.4,"savings":0,"reference":"5.4","old_building_value":5.4}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":510604,"demonstration_building_overridden":166920,"savings_programmed":"343684","savings_programmed_overridden":510604},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":130,"demonstration_building_overridden":68,"savings_programmed":"62","savings_programmed_overridden":130},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":50,"demonstration_building_overridden":93,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","national_requirements":18},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}}}}

SRT ID

cluster:zenn-site-grenoble-_refurbished-building-s-_arlequin-40-and-50-2-buildings

Building aspects