Skip to main content
European Commission logo
Smart Cities Marketplace

Implementation of new and retrofit DH/C energy supply

SRT Data

{"_id":"cluster:sinfonia-site-bolzano-_co-generation_implementation-of-new-and-retrofit-dh-c-energy-supply","_rev":"198-160a93fb25046596066a3a47e3a18b8f","document_type":"cluster","scis_id":"sinfonia-site-bolzano-_co-generation_implementation-of-new-and-retrofit-dh-c-energy-supply","cluster_type":"co-generation","energy_systems_general":{"energy_systems_technology_used_generation":"other","energy_systems_technology_used_generation_other":"combined heat and power plant (CHP)","energy_systems_year_completion":"2017"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_output_excl_peak_load","intervention_name":"Maximum thermal output of plant excluding peak load boiler","unit":"kWth","value":1847},{"key":"maximal_electrical_output","intervention_name":"maximum electrical output of plant","unit":"kWel","value":1824},{"key":"design_power_heat_ratio","intervention_name":"design power to heat ratio","unit":"kWel\/kWth","value":0.99},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":90}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Other","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":141.4},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.15}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"469888"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"77.8"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total Energy Generation [output] - Heat","unit":"kWh\/a","value":164931},{"key":"total_energy_generation_electricity","kpi_name":"Total Energy Generation [output] - Electricity","unit":"kWh\/a","value":365573},{"key":"energy_carrier_peak_load_supply","kpi_name":"Energy carrier for peak load supply","unit":"kWh\/a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":66442.1632,"savings_programmed":"28474.83679999999","reference_system":94917},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","reference_system":7000000}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","value":245614.34},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","value":140875},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a","value":13551},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a","value":16374},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","value":14000},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Other","kpi_name":"Total energy cost Other","unit":"\u20ac\/a","calculation":"70483.2"}],"social":{"new_building_social_jobs_created":2}},"revisions":[{"user":"rudy.rooth","date":"2019-03-21T09:33:13+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-03-21T09:33:23+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-05-27T12:43:40+01:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:05:46+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:06+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:31:02+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rudy.rooth","date":"2019-06-26T13:57:36+01:00","reason":"update"}]}

SRT ID

cluster:sinfonia-site-bolzano-_co-generation_implementation-of-new-and-retrofit-dh-c-energy-supply