Skip to main content
European Commission logo
Smart Cities Marketplace
Apply for technical assistance

Handellaan

SRT Data

{"_id":"cluster:sesac-site-delft_new-building-s-_handellaan","_rev":"37-12085ced297bed1fda0761c68d022d06","document_type":"cluster","scis_id":"sesac-site-delft_new-building-s-_handellaan","cluster_type":"new-building-s-","building_general":{"building_general_number_buildings":"1","building_general_number_year_completion":"2009"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":26,"building_general_total_heated_net_room_area":2588},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.37,"new_building_value":0.15},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.37,"new_building_value":0.19},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.37,"new_building_value":0.24},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":4.2,"new_building_value":1.2},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}]},"new_building_ec":{"renewable_energy_sources":[],"detailed_ec":[],"grid_electricity_price":"0.2","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":57,"savings":40,"reference":"97"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":18,"savings":38,"reference":"56"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":15,"savings":0,"reference":"15"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":24,"savings":2,"reference":"26"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","new_building_value":6144414},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":257166},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":90008},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"revisions":[{"user":"rudy.rooth","date":"2019-07-08T10:50:38+01:00","reason":"update"}]}

SRT ID

cluster:sesac-site-delft_new-building-s-_handellaan

Building aspects