Skip to main content
Smart Cities Marketplace
Scalable cities

3 Biomass boilers (3.5 MW) for district heating

SRT Data

{"_id":"cluster:cityfied-site-laguna-de-duero_boiler_3-biomass-boilers-3-5-mw-for-district-heating","_rev":"135-cf4b95fc6f415ca91ec28a02eeb562b5","document_type":"cluster","scis_id":"cityfied-site-laguna-de-duero_boiler_3-biomass-boilers-3-5-mw-for-district-heating","cluster_type":"boiler","energy_systems_general":{"energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_output_excl_peak_load","intervention_name":"Maximum thermal output of plant excluding peak load boiler","unit":"kWth","value":3450},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":87}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Domestic gas - grid-bound","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.037,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"6232594"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"84"}]},{"ec_name":"Wood Chips 30% moisture","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":0,"reference":"4","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.25,"reference":"1.06","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.028,"reference":"0.0361","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"9474558"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"80"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total Energy Generation [output] - Heat","unit":"kWh\/a","value":12815025},{"key":"energy_carrier_peak_load_supply","kpi_name":"Energy carrier for peak load supply","unit":"kWh\/a","value":2819.28}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":1252751.394,"demonstration_building_overridden":1252751.39},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":18512073.08,"demonstration_building_overridden":18512074}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Wood Chips 30% moisture","kpi_name":"Total energy cost Wood Chips 30% moisture","unit":"\u20ac\/a","calculation":"230605.978"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}},"revisions":[{"user":"rudy.rooth","date":"2018-12-05T14:06:50+00:00","reason":"update"},{"user":"rudy.rooth","date":"2018-12-05T14:10:07+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-01-30T07:25:04+00:00","reason":"Database update: _update_362_kpi_env_esi_no_m2 #362"},{"user":"alivas","date":"2019-05-06T09:09:55+02:00","reason":"update"},{"user":"alivas","date":"2019-05-07T13:59:17+02:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:05:46+01:00","reason":"Database update: updateDocsForKeyValue #667"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:02+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:56+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rudy.rooth","date":"2019-06-26T14:44:31+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T15:24:22+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T15:43:25+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T16:07:11+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T16:18:21+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T10:07:01+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-23T07:43:56+01:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:26:34+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:30:13+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T16:32:42+00:00","reason":"update"},{"user":"javier.martin","date":"2019-11-06T15:28:47+00:00","reason":"update"},{"user":"javier.martin","date":"2019-11-06T15:29:06+00:00","reason":"update"},{"user":"rudy.rooth","date":"2020-04-22T16:09:53+01:00","reason":"Renamed from 'cluster:cityfied-site-laguna-de-duero_boiler_3-biomass-boilers-3-5-mw-for-district-heating-rr' to 'cluster:cityfied-site-laguna-de-duero_boiler_3-biomass-boilers-3-5-mw-for-district-heating'"}],"mon":{"year_2017":{"energy_systems_general":{"energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_output_excl_peak_load","intervention_name":"Maximum thermal output of plant excluding peak load boiler","unit":"kWth","value":3450},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":87}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Domestic gas - grid-bound","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.037,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"4639000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"84"}]},{"ec_name":"Wood Chips 30% moisture","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":0,"reference":"4","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.25,"reference":"1.06","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.028,"reference":"0.0361","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"8043000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"80"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total Energy Generation [output] - Heat","unit":"kWh\/a","value":12682000},{"key":"energy_carrier_peak_load_supply","kpi_name":"Energy carrier for peak load supply","unit":"kWh\/a","value":2819.28}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":932439,"demonstration_building_overridden":932439,"savings_programmed":"-844380.48","reference_system":88058.52},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":15017480,"demonstration_building_overridden":15017480,"savings_programmed":"6816920","reference_system":21834400}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Wood Chips 30% moisture","kpi_name":"Total energy cost Wood Chips 30% moisture","unit":"\u20ac\/a","calculation":"171643"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}}},"year_2018":{"energy_systems_general":{"energy_systems_year_completion":"2014"},"energy_systems_interventions":{"interventions":[{"key":"maximal_thermal_output_excl_peak_load","intervention_name":"Maximum thermal output of plant excluding peak load boiler","unit":"kWth","value":3450},{"key":"heating_energy_input","intervention_name":"set temperature of heating energy output into district heating network","unit":"\u00b0C","value":87}]},"energy_systems_ec":{"detailed_ec":[{"ec_name":"Domestic gas - grid-bound","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.037,"reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"5886000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"84"}]},{"ec_name":"Wood Chips 30% moisture","ec_data":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":0,"reference":"4","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.25,"reference":"1.06","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.028,"reference":"0.0361","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"7518000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"80"}]}]},"energy_systems_kpis":{"technical":[{"key":"total_energy_generation_heating","kpi_name":"Total Energy Generation [output] - Heat","unit":"kWh\/a","value":10958640},{"key":"energy_carrier_peak_load_supply","kpi_name":"Energy carrier for peak load supply","unit":"kWh\/a","value":2819.28}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2\/a","demonstration_building_programmed":1183086,"demonstration_building_overridden":1183086,"savings_programmed":"-1095027.48","reference_system":88058.52},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/a","demonstration_building_programmed":15695520,"demonstration_building_overridden":15695520,"savings_programmed":"6138880","reference_system":21834400}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"net_energy_sales_electricity_grid","kpi_name":"Energy sales revenues for electricity","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_heating","kpi_name":"Energy sales revenues for delivered heating energy","unit":"\u20ac\/a"},{"key":"net_energy_sales_delivered_cooling","kpi_name":"Energy sales revenues for delivered cooling energy","unit":"\u20ac\/a"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"},{"key":"total_energy_cost_Wood Chips 30% moisture","kpi_name":"Total energy cost Wood Chips 30% moisture","unit":"\u20ac\/a","calculation":"217782"}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15,"new_building_floor_area":143025.36}}}}}

SRT ID

cluster:cityfied-site-laguna-de-duero_boiler_3-biomass-boilers-3-5-mw-for-district-heating