Skip to main content
Smart Cities Marketplace
Scalable cities

U4B-Energy system retrofit Physiology building

SRT Data

{"_id":"cluster:ruggedised-ume-_refurbished-building-s-_u4b-energy-system-retrofit-physiology-building","document_type":"cluster","scis_id":"ruggedised-ume-_refurbished-building-s-_u4b-energy-system-retrofit-physiology-building","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1,"building_general_number_year_completion":2019},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_number_apartments":0,"building_general_number_inhabitants":0,"building_general_number_occupants":4,"building_general_total_gross_floor_area":13497,"old_building_general_total_heated_net_room_area":13497,"building_general_total_heated_net_room_area":13497,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":13497},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2018},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.45,"old_building_value":0.45},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","new_building_value":0.21,"old_building_value":0.21},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","new_building_value":0.3,"old_building_value":0.3},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","new_building_value":0.23,"old_building_value":0.23},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":2.5,"old_building_value":2.5},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":50,"old_building_value":50}],"ict":"Building Energy Management System,Mobile applications for citizens","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":64,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.0334,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1436378"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"100"}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":43,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.06,"reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"935350"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"100"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":94.8,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.6,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.047,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"565008"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"100"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":64,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2021},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.034252,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":1121738},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":100}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":174000,"reference":0},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":30000,"reference":30000},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":46667,"reference":0},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":38421,"reference":39332,"calculation":"38421.769975999996"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":"139.7727771679473"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":90.4,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.6,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2021},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.0606,"reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":469501},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":100}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":174000,"reference":0},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":30000,"reference":30000},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":46667,"reference":0},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":28451,"reference":29139,"calculation":"28451.7606"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":"185.07703488372093"}]},{"technology":"district cooling (DC) network","ec_name":"Cold\/district cold","building_service":"cooling (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":43,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.06,"reference":"0.04","source":"RESCUE Project"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":1085196},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":100}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":174000,"reference":0},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":30000,"reference":30000},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":46667,"reference":0},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":65111,"reference":66656,"calculation":"65111.759999999995"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":"82.41618122977346"}]}],"grid_electricity_price":"0.2","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":198.3,"savings":4.699999999999989,"reference":203,"old_building_value":217.6},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":83.11,"savings":1.9699999999999989,"reference":85.08,"calculation":"83.11017263095502","old_building_value":106.42},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":40.4,"savings":41.910000000000004,"reference":82.31,"calculation":"80.40275616803734","old_building_value":69.3},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":0,"old_building_value":0},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":34.79,"savings":0.8200000000000003,"reference":35.61,"calculation":"34.785581981181004","old_building_value":41.86}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":185711,"demonstration_building_programmed":"160897.5504","demonstration_building_overridden":160898,"savings_programmed":"3814","savings_programmed_overridden":164712},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":3275741,"demonstration_building_overridden":2958135,"savings_programmed":"70135","savings_programmed_overridden":3028270},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":0,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":0,"new_building_value":522000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":0},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","national_requirements":90000,"new_building_value":90000},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":140000},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":135127,"new_building_value":131998,"calculation":"131985.290576"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","calculation":"-44.742729306487696"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":0,"new_building_social_jobs_created":1.45}},"revisions":[{"user":"Hans-Martin Neumann","date":"2020-10-05T12:35:09+01:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2021-10-01T16:35:52+02:00","reason":"Renamed from 'cluster:ruggedised-ume-_refurbished-building-s-_fysiologi---equipment-retrofit' to 'cluster:ruggedised-ume-_refurbished-building-s-_fysiologi---equipment-retrofit-u4b'"},{"user":"Tobias.Gunneberg","date":"2021-11-22T15:35:24+01:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2021-11-30T17:39:51+01:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2021-12-23T11:28:44+01:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2022-01-19T14:42:02+01:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2022-02-28T16:11:19+01:00","reason":"Renamed from 'cluster:ruggedised-ume-_refurbished-building-s-_fysiologi---equipment-retrofit-u4b' to 'cluster:ruggedised-ume-_refurbished-building-s-_u4b-energy-system-retrofit-physiology-building'"},{"user":"Tobias.Gunneberg","date":"2022-06-14T23:27:54+02:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2022-06-15T09:14:35+02:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2022-06-15T16:37:40+02:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2022-06-15T17:15:30+02:00","reason":"update"},{"user":"Tobias.Gunneberg","date":"2022-06-21T08:51:49+02:00","reason":"update"}]}

SRT ID

cluster:ruggedised-ume-_refurbished-building-s-_u4b-energy-system-retrofit-physiology-building