Skip to main content
Smart Cities Marketplace
Scalable cities

Youth Center Campoamor (Building integrated RES and energy storage A)

SRT Data

{"document_type":"cluster","scis_id":"matchup-valencia_refurbished-building-s-_youth-center-campoamor-building-integrated-res-and-energy-storage-a-","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1,"building_general_number_year_completion":2020},"building_general_technical":{"building_general_building_type":"municipal","old_building_general_total_heated_net_room_area":3462,"building_general_total_heated_net_room_area":3462,"old_building_general_total_cooled_net_room_area":3462,"building_general_total_cooled_net_room_area":3462},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)"},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)"},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)"},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)"},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":35864.55,"renewable_energy_financial":{}}],"old_detailed_ec":[{"technology":"electrical equipment","ec_name":"Electricity","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":331,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.368,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"152166"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"electrical equipment","ec_name":"Electricity","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":331,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.368,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":116301.86},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"24167.5265"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":43.95,"savings":0,"reference":43.95,"calculation":"43.9533","old_building_value":43.95},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":50367,"demonstration_building_programmed":"38495.9157","savings_programmed":"11871.0843","savings_programmed_overridden":50367},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":104.08,"demonstration_building_programmed":"89.9097","savings_programmed":"14.1703","savings_programmed_overridden":104.08},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_programmed":"23.5693","savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"24167.5265"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"_id":"cluster:matchup-valencia_refurbished-building-s-_youth-center-campoamor-building-integrated-res-and-energy-storage-a-","revisions":[{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T14:45:51+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T19:09:08+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T19:23:23+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T19:29:04+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T19:29:26+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T19:31:11+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-24T19:33:14+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-25T14:31:23+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-25T14:43:50+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-25T14:54:05+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-26T10:51:36+02:00","reason":"Renamed from 'cluster:matchup-valencia_refurbished-building-s-_yoth-center-campoamor-building-integrated-res-and-energy-storage-a-' to 'cluster:matchup-valencia_refurbished-building-s-_youth-center-campoamor-building-integrated-res-and-energy-storage-a-'"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-27T10:07:13+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-27T10:25:13+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-27T10:33:43+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-27T10:40:41+02:00","reason":"update"},{"user":"Juan Pablo Gonzalez Gutierrez","date":"2023-07-27T10:42:22+02:00","reason":"update"}],"mon":{"year_2021":{"building_general":{"building_general_number_buildings":1,"building_general_number_monitored_buildings":1,"building_general_number_year_completion":2020},"building_general_technical":{"building_general_building_type":"municipal","old_building_general_total_heated_net_room_area":3462,"building_general_total_heated_net_room_area":3462,"old_building_general_total_cooled_net_room_area":3462,"building_general_total_cooled_net_room_area":3462},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)"},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)"},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)"},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)"},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)"},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":30718,"renewable_energy_financial":{}}],"old_detailed_ec":[{"technology":"electrical equipment","ec_name":"Electricity","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":331,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.368,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"154706"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"electrical equipment","ec_name":"Electricity","building_service":"other please specify","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":331,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":2.368,"reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":123988},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"25764.7064"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":44.69,"savings":0,"reference":44.69,"calculation":"44.6869","old_building_value":44.69},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":51207.686,"demonstration_building_programmed":"41040.0280","savings_programmed":"10167.6580","savings_programmed_overridden":51207.686},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":105.82,"demonstration_building_programmed":"93.6804","savings_programmed":"12.1396","savings_programmed_overridden":105.82},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_programmed":"19.8557","savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"25764.7064"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}}}}

SRT ID

cluster:matchup-valencia_refurbished-building-s-_youth-center-campoamor-building-integrated-res-and-energy-storage-a-

Building aspects