SRT Data
{"document_type":"cluster","scis_id":"ruggedised-ume-_refurbished-building-s-_u4b---energy-system-retrofit-phyiology-building-ait","cluster_type":"refurbished-building-s-","building_general":{},"building_general_technical":{"building_general_building_type":"tertiary (non municipal)","building_general_total_heated_net_room_area":14560},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.6,"new_building_value":0.45,"old_building_value":0.45},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","new_building_value":0.21,"old_building_value":0.21},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","new_building_value":0.3,"old_building_value":0.3},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","new_building_value":0.23,"old_building_value":0.23},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","new_building_value":2.5,"old_building_value":2.5},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}]},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":205.79,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0.508,"reference":"1.36","source":"EN Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"1816600"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"88"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating (only)","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":198.5,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":0.4067,"reference":"1.36","source":"EN Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":1289200},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"64460.0000"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.2","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":88},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":88,"calculation":"88.5440"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"255906.2000"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":571612.1156},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"64460.0000"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"_id":"cluster:ruggedised-ume-_refurbished-building-s-_u4b---energy-system-retrofit-phyiology-building-ait","revisions":[{"user":"Daniel Horak","date":"2022-10-25T16:27:28+02:00","reason":"update"},{"user":"Daniel Horak","date":"2022-10-25T16:28:44+02:00","reason":"update"},{"user":"Daniel Horak","date":"2022-10-25T16:30:53+02:00","reason":"update"},{"user":"Daniel Horak","date":"2022-11-03T11:14:10+01:00","reason":"update"}],"mon":{}}
SRT ID
cluster:ruggedised-ume-_refurbished-building-s-_u4b---energy-system-retrofit-phyiology-building-ait