Skip to main content
European Commission logo
Smart Cities Marketplace

Demo Site Project Herbortgasse 43

SRT Data

{"document_type":"cluster","scis_id":"smarter-together-site-vienna-_refurbished-building-s-_demo-site-project-herbortgasse-43","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":4,"building_general_number_monitored_buildings":4},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":41,"building_general_number_inhabitants":91,"old_building_general_total_heated_net_room_area":2728,"building_general_total_heated_net_room_area":3781},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","old_building_value":1.19},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.2,"new_building_value":0.19,"old_building_value":0.66},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.35,"new_building_value":0.17,"old_building_value":1.18},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.2,"new_building_value":0.21,"old_building_value":1.04},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":1.4,"old_building_value":2.15},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%"}]},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":313.9,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"195407"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":247,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"105219"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":248,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":313.9,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":199826},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"9991.300000000001"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"boiler","ec_name":"Domestic gas - grid-bound","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":247,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.0664","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":107599},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"7144.5736"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":248,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.22","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":46.3,"savings":25.700000000000003,"reference":72},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":35,"savings":3.200000000000003,"reference":38.2},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":2358700},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"17135.8736"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":94}},"_id":"cluster:smarter-together-site-vienna-_refurbished-building-s-_demo-site-project-herbortgasse-43","revisions":[{"user":"Daniel Horak","date":"2021-09-27T15:40:43+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-09-27T17:39:30+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-05T16:11:43+02:00","reason":"update"}]}

SRT ID

cluster:smarter-together-site-vienna-_refurbished-building-s-_demo-site-project-herbortgasse-43

Building aspects