Skip to main content
Smart Cities Marketplace

Demo Site Project Hauffgasse 37-47

SRT Data

{"document_type":"cluster","scis_id":"smarter-together-site-vienna-_refurbished-building-s-_demo-site-project-hauffgasse-37-47","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":3,"building_general_number_monitored_buildings":3,"building_general_number_year_completion":1983},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":486,"building_general_number_inhabitants":1051,"old_building_general_total_heated_net_room_area":53641,"building_general_total_heated_net_room_area":61054},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements"},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","old_building_value":1.28},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.2,"new_building_value":0.18,"old_building_value":0.36},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.35,"new_building_value":0.17,"old_building_value":1.07},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.2,"new_building_value":0.13,"old_building_value":0.39},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":1.4,"new_building_value":1,"old_building_value":3},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","new_building_value":0.5,"old_building_value":0.67}]},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":47800,"renewable_energy_financial":{}}],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":247,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"5176357"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":248,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"311118"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":247,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":4975901},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"248795.05000000002"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]},{"technology":"electrical equipment","ec_name":"Electricity","building_service":"lighting and appliances","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":248,"reference":"617","source":"EN  Standard - 15603"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"3.31","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2019},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.2078","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":256427},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","calculation":"53285.530600000006"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.22","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":85.7,"savings":78.60000000000001,"reference":164.3,"calculation":"86.48291676221051"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":39.3,"savings":72.9,"reference":112.2},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":42.2,"savings":4.099999999999994,"reference":46.3},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":4.2,"savings":1.5999999999999996,"reference":5.8,"calculation":"4.200003275788646"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"1292641.443","savings_programmed":"63075.55700000003","savings_programmed_overridden":1355717},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"125.52492432928229"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.905281084094931"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac"},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac"},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac"},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","calculation":"302080.58060000004"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{"new_building_social_citizens_involved":1051}},"_id":"cluster:smarter-together-site-vienna-_refurbished-building-s-_demo-site-project-hauffgasse-37-47","revisions":[{"user":"Daniel Horak","date":"2021-09-27T14:17:52+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-09-27T17:46:53+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-04T09:06:13+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-04T09:07:47+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-04T16:08:59+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-04T16:31:11+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-04T16:53:21+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-04T16:55:07+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-05T14:58:57+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-05T15:50:40+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-05T15:58:20+02:00","reason":"update"},{"user":"Daniel Horak","date":"2021-10-05T17:32:02+02:00","reason":"update"}]}

SRT ID

cluster:smarter-together-site-vienna-_refurbished-building-s-_demo-site-project-hauffgasse-37-47

Building aspects