Skip to main content
Smart Cities Marketplace
Scalable cities

Kv. Isbanan

SRT Data

{"_id":"cluster:next-buildings-site-helsingborg_new-building-s-_kv-isbanan","_rev":"247-a3273bac572a35c7691297b93b530b4b","document_type":"cluster","scis_id":"next-buildings-site-helsingborg_new-building-s-_kv-isbanan","building_general":{"building_general_number_buildings":"3","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"2016"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":111,"building_general_number_inhabitants":210,"building_general_number_occupants":210,"building_general_total_gross_floor_area":10704,"building_general_total_heated_net_room_area":9583,"building_general_total_cooled_net_room_area":9583},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2015,"new_building_value":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.35,"new_building_value":0.1},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.04},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.25,"new_building_value":0.14},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.3,"new_building_value":0.11},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2,"new_building_value":0.9},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":50}],"ict":"Building Energy Management System,Neighbourhood Energy Management System","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":21155,"renewable_energy_financial":{"total_investment_costs":125736,"total_operating_costs":629,"feed_tariff":77}},{"installed_sources":"solar thermal collectors","renewable_energy_financial":{}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac"},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a"},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac"},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}],"grid_electricity_price":"0.1","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":41,"savings":85,"reference":"126"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":10,"savings":56,"reference":"66"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":18,"savings":10,"reference":"28"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":12,"savings":20,"reference":"32"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":16298053,"new_building_value":17200000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":901947},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":553200},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":106980,"new_building_value":34290},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":12.4},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}},"monitoring_data":{"monitoring_object":[{"monitoring_general_data":[],"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","renewable_energy_financial":[]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year"},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%"}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a"},{"key":"total_energy_cost","label":"Total energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a"}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a"},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a"},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%"}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2016"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":21155,"renewable_energy_financial":{"total_operating_costs":629,"feed_tariff":77}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":38,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.06,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":259793},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":11}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":171443,"reference":"160526","calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":171443,"reference":"160526","calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":8,"reference":"NaN","calculation":""}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":31,"savings":110,"reference":"141","calculation":"29.317332776792234"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":18,"savings":56,"reference":"74","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":10,"savings":22,"reference":"32","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":3,"savings":33,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"38","demonstration_building_overridden":11000,"savings_programmed":"27100","savings_programmed_overridden":38100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"259793","demonstration_building_overridden":31,"savings_programmed":"110","savings_programmed_overridden":141},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.000007857521838179604","demonstration_building_overridden":14.7,"savings_programmed":"-14.7","savings_programmed_overridden":0}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":19426},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","reference":8},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}},{"monitoring_general_data":{"monitoring_general_data_year":"2017"},"monitoring_energy_data":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":31131,"renewable_energy_financial":{"total_operating_costs":629}},{"installed_sources":"solar thermal collectors","installed_heat":19684,"renewable_energy_financial":{"total_operating_costs":0}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":0.38,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":250978},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":13.6}],"ec_data_financial":[{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":418369,"reference":"407451 ","calculation":""},{"key":"total_energy_cost","label":"Total operating costs","unit":"\u20ac\/a","value":418369,"reference":"407451 ","calculation":""},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","calculation":""}]}]},"monitoring_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":34,"savings":107,"reference":"140","calculation":"31.49253887091725"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":17,"savings":57,"reference":"74","calculation":"0"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0","calculation":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":9,"savings":22,"reference":"31","calculation":"0"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":2,"savings":34,"reference":"36","calculation":"0"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"0.38","demonstration_building_overridden":11600,"savings_programmed":"26500","savings_programmed_overridden":38100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_programmed":"250978","demonstration_building_overridden":34,"savings_programmed":"107","savings_programmed_overridden":141},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_programmed":"0.000017570385070356636","demonstration_building_overridden":20,"savings_programmed":"-20","savings_programmed_overridden":0}],"economic":[{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","reference":25441},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a"},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}]}}]},"cluster_type":"new-building-s-","revisions":[{"user":"rudy.rooth","date":"2018-08-01T12:29:11+01:00"},{"user":"Clemens Tolboom","date":"2018-11-01T13:37:02+00:00","reason":"Database update: _update_357_StandardValuesFromNorm #357"},{"user":"Clemens Tolboom","date":"2018-12-11T10:39:54+00:00","reason":"Database update: _update_539_ChangeUnitKWha #539"},{"user":"Clemens Tolboom","date":"2018-12-12T13:50:38+00:00","reason":"Database update: _update_587_foa_fix_energy_costs #587: fixing energy costs"},{"user":"Clemens Tolboom","date":"2019-01-30T07:26:14+00:00","reason":"Database update: updateDocsForKeyValue #636"},{"user":"Clemens Tolboom","date":"2019-01-30T07:29:13+00:00","reason":"Database update: _update_639_ROI_is_on_not_of #639"},{"user":"rudy.rooth","date":"2019-02-07T09:46:45+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T11:51:54+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-02-08T12:00:16+00:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-02-14T09:53:38+00:00","reason":"Database update: updateDocsForKeyValue #650"},{"user":"Clemens Tolboom","date":"2019-02-14T09:56:20+00:00","reason":"Database update: updateDocsForKeyValue #655"},{"user":"Clemens Tolboom","date":"2019-02-21T13:27:28+00:00","reason":"Database update: updateDocsForKeyValue #677"},{"user":"Clemens Tolboom","date":"2019-06-07T09:15:47+01:00","reason":"Database update: updateDocsForKeyValue #703"},{"user":"Clemens Tolboom","date":"2019-06-07T09:18:08+01:00","reason":"Database update: updateDocsRemoveKey #711"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:04+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:58+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rudy.rooth","date":"2019-06-13T13:19:26+01:00","reason":"update"},{"user":"rudy.rooth","date":"2019-06-13T13:19:42+01:00","reason":"update"},{"user":"rudy.rooth","date":"2019-06-13T13:20:02+01:00","reason":"update"},{"user":"rudy.rooth","date":"2019-06-13T13:54:30+01:00","reason":"update"},{"user":"admin","date":"2019-07-24T12:28:41+02:00","reason":"update"},{"user":"admin","date":"2019-07-24T12:29:19+02:00","reason":"update"},{"user":"admin","date":"2019-08-15T14:20:00+02:00","reason":"Database update: updateDocsForKeyValue #418"},{"user":"admin","date":"2019-08-15T14:25:58+02:00","reason":"Database update: updateDocsForKeyValue #836"}],"mon":{"year_2016":{"building_general":{"building_general_number_buildings":"3","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"2016"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":111,"building_general_number_inhabitants":210,"building_general_number_occupants":210,"building_general_total_gross_floor_area":10704,"building_general_total_heated_net_room_area":9583,"building_general_total_cooled_net_room_area":9583},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2015,"new_building_value":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.35,"new_building_value":0.1},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.04},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.25,"new_building_value":0.14},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.3,"new_building_value":0.11},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2,"new_building_value":0.9},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":50}],"ict":"Building Energy Management System,Neighbourhood Energy Management System","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":21155,"renewable_energy_financial":{"total_investment_costs":125736,"total_operating_costs":629,"feed_tariff":77}},{"installed_sources":"solar thermal collectors","renewable_energy_financial":{}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":38,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2016},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.06,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"259793"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"11"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":21500000,"reference":"20372566","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":171443,"reference":"160526","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":553200,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":31334,"reference":"134596","calculation":"15587.58"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":6.9,"calculation":"6.218355081487899"}]}],"grid_electricity_price":"0.1","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":31,"savings":110,"reference":"141"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":18,"savings":56,"reference":"74"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":10,"savings":22,"reference":"32"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":3,"savings":33,"reference":"36"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"9872.134","demonstration_building_overridden":11000,"savings_programmed":"27100","savings_programmed_overridden":38100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":31,"savings_programmed":"110","savings_programmed_overridden":141},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_overridden":14.7,"savings_programmed_overridden":0}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":16298053,"new_building_value":17200000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":901947},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":553200},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":106980,"new_building_value":19426,"calculation":"15587.58"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":8},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}},"year_2017":{"building_general":{"building_general_number_buildings":"3","building_general_number_monitored_buildings":"3","building_general_number_year_completion":"2016"},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":111,"building_general_number_inhabitants":210,"building_general_number_occupants":210,"building_general_total_gross_floor_area":10704,"building_general_total_heated_net_room_area":9583,"building_general_total_cooled_net_room_area":9583},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2015,"new_building_value":2015},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.35,"new_building_value":0.1},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.4,"new_building_value":0.04},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.25,"new_building_value":0.14},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.3,"new_building_value":0.11},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2,"new_building_value":0.9},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":60,"new_building_value":50}],"ict":"Building Energy Management System,Neighbourhood Energy Management System","building_features":"Active ventilation control"},"new_building_ec":{"renewable_energy_sources":[{"installed_sources":"photovoltaic","installed_electricity":31131,"renewable_energy_financial":{"total_investment_costs":125736,"total_operating_costs":629,"feed_tariff":77}},{"installed_sources":"solar thermal collectors","renewable_energy_financial":{}}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":38,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2017},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.07,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"250978"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"13.6"}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":21500000,"reference":"20372566","calculation":""},{"key":"total_operating_costs","label":"Total Operating costs (in \u20ac\/a)","unit":"\u20ac\/a","value":418369,"reference":"407451","calculation":""},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":553200,"reference":"0","calculation":""},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":31334,"reference":"134596","calculation":"17568.460000000003"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":6.9,"calculation":"6.218422420514598"}]}],"grid_electricity_price":"0.1","demo_site_fuel_cost":"0.07"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":34,"savings":106,"reference":"140"},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":17,"savings":57,"reference":"74"},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0,"savings":0,"reference":"0"},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":9,"savings":22,"reference":"31"},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a","demo_building":2,"savings":34,"reference":"36"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","demonstration_building_programmed":"9537.164","demonstration_building_overridden":11600,"savings_programmed":"26500","savings_programmed_overridden":38100},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","demonstration_building_overridden":34,"savings_programmed":"107","savings_programmed_overridden":141},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","demonstration_building_overridden":20}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":16298053,"new_building_value":17200000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","national_requirements":0,"new_building_value":901947},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac"},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","national_requirements":0,"new_building_value":553200},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","national_requirements":106980,"new_building_value":25441,"calculation":"17568.460000000003"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":12.4},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%"}],"social":{}}}}}

SRT ID

cluster:next-buildings-site-helsingborg_new-building-s-_kv-isbanan