Skip to main content
Smart Cities Marketplace
Scalable cities

31 residential buildings (143,025.36 m²; 1,488 dwellings)

SRT Data

{"_id":"cluster:cityfied-site-laguna-de-duero_refurbished-building-s-_31-residential-buildings-143-025-36-m-1-488-dwellings-","_rev":"164-b191195838a4baa33a4560f140d3f411","document_type":"cluster","scis_id":"cityfied-site-laguna-de-duero_refurbished-building-s-_31-residential-buildings-143-025-36-m-1-488-dwellings-","cluster_type":"refurbished-building-s-","building_general":{"building_general_number_buildings":31,"building_general_number_monitored_buildings":31,"building_general_number_year_completion":1980},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":1488,"building_general_number_inhabitants":4000,"building_general_total_gross_floor_area":174600,"old_building_general_total_heated_net_room_area":143025.36,"building_general_total_heated_net_room_area":143025.36,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":0},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2013,"new_building_value":2016,"old_building_value":2011},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":0.34,"old_building_value":1.36},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.38,"new_building_value":0.82,"old_building_value":0.82},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":0.34,"old_building_value":1.36},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.49,"new_building_value":0.9,"old_building_value":0.9},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.7,"new_building_value":3.75,"old_building_value":3.75},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":61,"new_building_value":76,"old_building_value":76}],"ict":"Building Energy Management System,Neighbourhood Energy Management System"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.04,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"15491000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"70"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":88,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.17,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.032,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":9488000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":70}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":16655000},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":261000},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":7632944},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":600000,"calculation":"303616"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":16}]}],"grid_electricity_price":"0.103","demo_site_fuel_cost":"0.04"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":76.7,"savings":9.83,"reference":86.53,"old_building_value":109.78},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":47.44,"savings":22.31,"reference":69.75,"old_building_value":93},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":29.26,"savings":-12.48,"reference":16.78,"old_building_value":16.78},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":3113691,"demonstration_building_programmed":"834944","demonstration_building_overridden":834944,"savings_programmed":"-746885.48","savings_programmed_overridden":88058.52},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":118.4,"demonstration_building_overridden":79.29,"savings_programmed":"76.67","savings_programmed_overridden":155.96},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":59.41}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":11582191.78,"new_building_value":14000000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":2500000},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","new_building_value":111850},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":8000000},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":598527,"calculation":"303616"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":19.72},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":49.63}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15}},"revisions":[{"user":"rudy.rooth","date":"2018-12-05T14:48:13+00:00","reason":"update"},{"user":"rudy.rooth","date":"2018-12-05T14:50:36+00:00","reason":"update"},{"user":"rudy.rooth","date":"2018-12-05T15:02:59+00:00","reason":"update"},{"user":"rudy.rooth","date":"2018-12-05T15:04:17+00:00","reason":"update"},{"user":"javier.martin","date":"2019-05-27T16:50:33+01:00","reason":"update"},{"user":"javier.martin","date":"2019-05-28T16:32:38+01:00","reason":"update"},{"user":"Clemens Tolboom","date":"2019-06-07T09:28:02+01:00","reason":"Database update: updateDocsForKeyValue #748"},{"user":"Clemens Tolboom","date":"2019-06-07T09:30:56+01:00","reason":"Database update: updateDocsForKeyValue #773"},{"user":"rudy.rooth","date":"2019-06-13T14:14:56+01:00","reason":"update"},{"user":"rudy.rooth","date":"2019-06-13T14:16:39+01:00","reason":"update"},{"user":"rudy.rooth","date":"2019-06-26T12:38:17+01:00","reason":"update"},{"user":"javier.martin","date":"2019-07-22T12:17:13+01:00","reason":"update"},{"user":"javier.martin","date":"2019-07-25T08:41:01+01:00","reason":"update"},{"user":"javier.martin","date":"2019-07-25T08:45:46+01:00","reason":"update"},{"user":"javier.martin","date":"2019-07-25T09:28:44+01:00","reason":"update"},{"user":"admin","date":"2019-08-15T14:25:56+02:00","reason":"Database update: updateDocsForKeyValue #836"},{"user":"javier.martin","date":"2019-08-20T15:57:55+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-20T16:19:51+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T09:31:55+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T10:28:19+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T10:28:42+01:00","reason":"update"},{"user":"javier.martin","date":"2019-08-21T10:31:11+01:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T09:00:01+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T15:14:01+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T15:35:57+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T15:41:21+00:00","reason":"update"},{"user":"javier.martin","date":"2019-10-28T15:49:09+00:00","reason":"update"},{"user":"javier.martin","date":"2019-11-06T15:20:33+00:00","reason":"update"},{"user":"javier.martin","date":"2019-11-06T15:21:33+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-11-28T15:54:17+00:00","reason":"update"},{"user":"rudy.rooth","date":"2019-11-28T15:58:53+00:00","reason":"update"},{"user":"rudy.rooth","date":"2020-03-04T11:11:27+00:00","reason":"update"},{"user":"rudy.rooth","date":"2020-04-22T16:09:53+01:00","reason":"Renamed from 'cluster:cityfied-site-laguna-de-duero_refurbished-building-s-_31-residential-buildings-143-025-36-m-1-488-dwellings--rr' to 'cluster:cityfied-site-laguna-de-duero_refurbished-building-s-_31-residential-buildings-143-025-36-m-1-488-dwellings-'"}],"mon":{"year_2017":{"building_general":{"building_general_number_buildings":31,"building_general_number_monitored_buildings":31,"building_general_number_year_completion":1980},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":1488,"building_general_number_inhabitants":4000,"building_general_total_gross_floor_area":174600,"old_building_general_total_heated_net_room_area":143025.36,"building_general_total_heated_net_room_area":143025.36,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":0},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2013,"new_building_value":2016,"old_building_value":2011},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":0.34,"old_building_value":1.36},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.38,"new_building_value":0.82,"old_building_value":0.82},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":0.34,"old_building_value":1.36},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.49,"new_building_value":0.9,"old_building_value":0.9},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.7,"new_building_value":3.75,"old_building_value":3.75},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":61,"new_building_value":76,"old_building_value":76}],"ict":"Building Energy Management System,Neighbourhood Energy Management System"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.04,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"15491000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"70"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":88,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.17,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.032,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":12682000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":70}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":16655000},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":261000},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":7632944},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":600000,"calculation":"405824"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":16}]}],"grid_electricity_price":"0.103","demo_site_fuel_cost":"0.04"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":77.2,"savings":9.33,"reference":86.53,"old_building_value":109.78},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":63.41,"savings":6.34,"reference":69.75,"old_building_value":93},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":13.79,"savings":2.99,"reference":16.78,"old_building_value":16.78},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":3113691,"demonstration_building_programmed":"1116016","demonstration_building_overridden":1116016,"savings_programmed":"-1027957.48","savings_programmed_overridden":88058.52},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":118.4,"demonstration_building_overridden":105.99,"savings_programmed":"49.97000000000001","savings_programmed_overridden":155.96},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":63.42}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":11582191.78,"new_building_value":14000000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":2500000},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","new_building_value":111850},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":8000000},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":598527,"calculation":"405824"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":19.72},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":49.63}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15}}},"year_2018":{"building_general":{"building_general_number_buildings":31,"building_general_number_monitored_buildings":31,"building_general_number_year_completion":1980},"building_general_technical":{"building_general_building_type":"residential","building_general_number_apartments":1488,"building_general_number_inhabitants":4000,"building_general_total_gross_floor_area":174600,"old_building_general_total_heated_net_room_area":143025.36,"building_general_total_heated_net_room_area":143025.36,"old_building_general_total_cooled_net_room_area":0,"building_general_total_cooled_net_room_area":0},"new_building_interventions":{"high_performance_new_buildings":[{"key":"year_national_requirements","kpi_name":"Year - National Requirements","national_requirements":2013,"new_building_value":2016,"old_building_value":2011},{"key":"overall_average_htc_building","kpi_name":"overall average HTC of the building envelope surfaces","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":0.34,"old_building_value":1.36},{"key":"average_htc_roof","kpi_name":"average HTC roof ","unit":"W\/(m\u00b2K)","national_requirements":0.38,"new_building_value":0.82,"old_building_value":0.82},{"key":"average_htc_facade_walls","kpi_name":"average HTC facade\/external walls","unit":"W\/(m\u00b2K)","national_requirements":0.66,"new_building_value":0.34,"old_building_value":1.36},{"key":"average_htc_ground_floor","kpi_name":"average HTC ground floor","unit":"W\/(m\u00b2K)","national_requirements":0.49,"new_building_value":0.9,"old_building_value":0.9},{"key":"average_htc_windows","kpi_name":"average HTC windows (frame and pane)","unit":"W\/(m\u00b2K)","national_requirements":2.7,"new_building_value":3.75,"old_building_value":3.75},{"key":"average_energy_windows","kpi_name":"average energy transmittance of windows (g-value)","unit":"%","national_requirements":61,"new_building_value":76,"old_building_value":76}],"ict":"Building Energy Management System,Neighbourhood Energy Management System"},"new_building_ec":{"renewable_energy_sources":[],"old_detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-eq\/kWh","factor":201,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.07,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2014},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.04,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":"15491000"},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":"70"}]}],"detailed_ec":[{"technology":"district heating (DH) network","ec_name":"Heat\/district heat","building_service":"heating and DHW","ec_data_environmental":[{"key":"co2_greenhouse","label":"Greenhouse Gas Emissions (CO2-equivalent) factor","unit":"gCO2-equ\/kWh","factor":88,"reference":"305","source":"Eurostat"},{"key":"primary_energy_factor","label":"Primary Energy Factor","unit":"kWhPE\/kWhFE","factor":1.17,"reference":"1.36","source":"EN  Standard - 15603"},{"key":"energy_cost_year","label":"Year of collection of energy price","unit":"Year","factor":2018},{"key":"energy_cost","label":"Energy price (Energy carrier), excluding VAT, grants","unit":"\u20ac\/kWh","factor":0.032,"reference":"0.05","source":"Eurostat"}],"ec_data_consumption":[{"key":"final_energy_input","label":"FINAL ENERGY INPUT","unit":"kWh\/a","value":13404000},{"key":"total_system_performance","label":"Overall System Performance (output divided by input)","unit":"%","value":70}],"ec_data_financial":[{"key":"total_investment","label":"Total investment costs","unit":"\u20ac","value":16655000},{"key":"total_operating_costs","label":"Total operating costs","unit":"EUR\/a","value":261000},{"key":"grants","label":"Grants and subsidies","unit":"\u20ac","value":7632944},{"key":"total_energy_cost","label":"Total energy costs","unit":"\u20ac\/a","value":600000,"calculation":"428928"},{"key":"dynamic_payback_period","label":"Dynamic payback period","unit":"a","value":16}]}],"grid_electricity_price":"0.103","demo_site_fuel_cost":"0.04"},"new_building_kpis":{"technical":[{"key":"total_final_energy","kpi_name":"Total Final Energy Demand","unit":"kWh\/m2a","demo_building":95.74,"savings":-9.21,"reference":86.53,"old_building_value":109.78},{"key":"final_energy_demand_heating","kpi_name":"Final Energy Demand for Space Heating","unit":"kWh\/m2a","demo_building":77.64,"savings":-7.89,"reference":69.75,"old_building_value":93},{"key":"final_energy_demand_cooling","kpi_name":"Final Energy Demand for Cooling","unit":"kWh\/m2a","demo_building":0},{"key":"final_energy_demand_hot_water","kpi_name":"Final Energy Demand for Domestic Hot Water","unit":"kWh\/m2a","demo_building":18.1,"savings":-1.32,"reference":16.78,"old_building_value":16.78},{"key":"final_energy_demand_electricity","kpi_name":"Final Energy Demand Electricity","unit":"kWh\/m2a"}],"environmental":[{"key":"total_co2_emissions","kpi_name":"Total CO2 Emissions","unit":"kgCO2eq\/a","old_building_value":3113691,"demonstration_building_programmed":"1179552","demonstration_building_overridden":1179552,"savings_programmed":"-1091493.48","savings_programmed_overridden":88058.52},{"key":"final_total_primary_energy_demand","kpi_name":"Total Primary Energy Demand","unit":"kWh\/m2a","old_building_value":118.4,"demonstration_building_overridden":112.02,"savings_programmed":"43.94000000000001","savings_programmed_overridden":155.96},{"key":"final_total_local_renewable_energy","kpi_name":"Total Share of Local Renewable Energy","unit":"%","old_building_value":0,"demonstration_building_overridden":56.09}],"economic":[{"key":"total_investment","kpi_name":"Total Investments (excl. VAT)","unit":"\u20ac","national_requirements":11582191.78,"new_building_value":14000000},{"key":"final_additional_energy_investment","kpi_name":"Total additional Energy Related Investments","unit":"\u20ac","new_building_value":2500000},{"key":"total_operating_costs","kpi_name":"Total Operating costs","unit":"\u20ac\/a","new_building_value":111850},{"key":"grants","kpi_name":"Grants","unit":"\u20ac","new_building_value":8000000},{"key":"total_energy_cost_year","kpi_name":"Total Energy cost per year","unit":"\u20ac\/a","new_building_value":598527,"calculation":"428928"},{"key":"dynamic_payback_period","kpi_name":"Dynamic Payback Period","unit":"a","new_building_value":19.72},{"key":"return_investment","kpi_name":"Return on Investment","unit":"%","new_building_value":49.63}],"social":{"new_building_social_citizens_involved":4500,"new_building_social_jobs_created":15}}}}}

SRT ID

cluster:cityfied-site-laguna-de-duero_refurbished-building-s-_31-residential-buildings-143-025-36-m-1-488-dwellings-

Building aspects